Your Cart
Menu
  • Product Groups
    • Antenna Alignment
    • Aviation
    • Cable & Antenna Analysers
    • Calibration Kits
    • EMC
    • Meters
    • Network Analysers
    • Optical Test Equipment
    • Oscilloscopes
    • PIM Masters
    • Power Sensors
    • Power Supplies
    • RF Amplifiers
    • Safety Monitors
    • RF Shielded Boxes
    • Signal / Spectrum Analysers
    • Signal Generators
    • Temperature
    • Wireless Testers
  • Manufacturers
    • 3Z Telecom
    • Amplifier Research
    • Anritsu
    • Compliance West
    • EXFO
    • FieldSENSE
    • Fluke
    • Haefely Hipotronics
    • Keysight
    • Litepoint
    • Megger
    • Narda STS
    • Rohde & Schwarz
    • ShinewayTech
    • Sunsight Instruments
    • Tektronix
    • Tescom
    • Viavi
    • Vötsch
  • About us
  • Looking to Buy New?
  • Calibration
  • Components
  • Contact
MCS Rentals
    Customer Login Phone: 01492 643 060
    Email: sales@mcsrentals.com
    Menu
    MCS Rentals
    MCS Rentals
    • Product Groups
      • Antenna Alignment
      • Aviation
      • Cable & Antenna Analysers
      • Calibration Kits
      • EMC
      • Meters
      • Network Analysers
      • Optical Test Equipment
      • Oscilloscopes
      • PIM Masters
      • Power Sensors
      • Power Supplies
      • RF Amplifiers
      • Safety Monitors
      • RF Shielded Boxes
      • Signal / Spectrum Analysers
      • Signal Generators
      • Temperature
      • Wireless Testers
    • Manufacturers
      • 3Z Telecom
      • Amplifier Research
      • Anritsu
      • Compliance West
      • EXFO
      • FieldSENSE
      • Fluke
      • Haefely Hipotronics
      • Keysight
      • Litepoint
      • Megger
      • Narda STS
      • Rohde & Schwarz
      • ShinewayTech
      • Sunsight Instruments
      • Tektronix
      • Tescom
      • Viavi
      • Vötsch
    • About us
    • Looking to Buy New?
    • Calibration
    • Components
    • Contact
    Shop Departments
    • 3Z Telecom
    • Amplifier Research
    • Anritsu
      • Antenna Analysers
      • Cable Analysers
      • PIM Masters
      • Site Masters
    • Fluke Networks
    • Haefely Hipotronics
    • LitePoint
    • Keysight Technologies
    • Narda STS
    • Rohde & Schwarz
      • Network Analysers
      • Power Sensors
      • Spectrum Analysers
      • Signal Generators
    • ShinewayTech
    • Sunsight Instruments
    • Tektronix
    • Tescom
    • Viavi
    • MCS RentalsHome
    • EMC
    • EMC
    Latest Products
    Rohde & Schwarz CBT Bluetooth Tester | MCS Rentals
    Rohde & Schwarz CBT Bluetooth Tester
    $0.00
    Rohde & Schwarz CMW-Z10 RF Shield Box | MCS Rentals
    Rohde & Schwarz CMW-Z10 RF Shield Box
    $0.00
    Rohde & Schwarz CMW290 Functional Communications Tester | MCS Rentals
    Rohde & Schwarz CMW290 Functional Communications Tester
    $0.00
    Rohde & Schwarz CMW500 Wideband Communications Tester | MCS Rentals
    Rohde & Schwarz CMW500 Wideband Communications Tester
    $0.00
    LitePoint IQcell Multi-Device Signalling Test Solution | MCS Rentals
    LitePoint IQcell Multi-Device Signalling Test Solution
    $0.00
    Narda STS Nardalert S3 Personal Radiation Monitor | MCS Rentals
    Narda STS Nardalert S3 Personal Radiation Monitor
    $0.00

    EMC (Electromagnetic Compatibility) Test Equipment


    EMC (Electromagnetic Compatibility), is the interaction of electrical and electronic equipment with its electromagnetic environment, and with other equipment. All electronic devices have the potential to emit electromagnetic fields. With the proliferation of electronic devices into everyday life - TVs, washing machines, electronic ignitions, traffic lights, mobile phones, ATMs, anti-theft tags, to name but a few - there is therefore a huge potential for devices to interfere with each other.

    EMC

    {"id":3498679107662,"title":"Haefely Hipotronics ONYX 16 Electrostatic Discharge Test System","handle":"haefely-hipotronics-onyx-16-electrostatic-discharge-test-system","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHaefely Hipotronics ONYX 16 Electrostatic Discharge Test System Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Haefely Hipotronics ONYX 16 is a state of the art electrostatic discharge simulator available in 16 kV or 30 kV versions. It is the most ergonomic ESD simulator without any additional base control unit that can be battery or mains operated. The easy to use touch screen, ergonomic design, modular RC units, multilingual interface, remote control software, built-in LED light and temperature \u0026amp; humidity display allows for trouble-free use of the ONYX in all types of test sites. The ONYX also includes a bleeder resistor which is connected in parallel with the output of the high-voltage power supply circuit. This ensures that the high voltage power supply is completely discharged after each injected pulse to an EUT or if the ESD simulator itself will be turned-off by the user (bleed-off).\u003cbr\u003e\u003cbr\u003eThe smart key button, integrated into the trigger button has various functions that can be defined by the user including polarity switching, LED light, counter reset, voltage stepping up\/down and others. \u003cbr\u003e\u003cbr\u003eThe ONYX also features a unique self test which verifies all of the main components of the unit are working correctly. This ensures that accurate and reliable tests are performed every time the gun is used.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHaefely Hipotronics ONYX 16 Electrostatic Discharge Test System Specification\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications - Scope of Supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"1\" cellpadding=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir discharge voltage\u003c\/td\u003e\n\u003ctd\u003e1 .. 16 kV or 1 .. 30 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage resolution\u003c\/td\u003e\n\u003ctd\u003e100 V steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCont. discharge voltage\u003c\/td\u003e\n\u003ctd\u003e1 .. 16 kV or 1 .. 30 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge polarity\u003c\/td\u003e\n\u003ctd\u003epositive \u0026amp; negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge repetition\u003c\/td\u003e\n\u003ctd\u003esingle\/0.1\/0.2\/0.5\/1\/2\/5\/10\/20 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating modes\u003c\/td\u003e\n\u003ctd\u003esingle \u0026amp; continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge counter\u003c\/td\u003e\n\u003ctd\u003e1 .. 9999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 16 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault R\/C – network\u003c\/td\u003e\n\u003ctd\u003e150 pF \/ 330 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e17 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e290 x 270 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cbr\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Haefely_Hipotronics_ONYX_16_Electrostatic_Discharge_Test_System_Datasheet.pdf?1020\" title=\"Haefely Hipotronics ONYX 16 Electrostatic Discharge Test System\"\u003eHaefely Hipotronics ONYX 16 Electrostatic Discharge Test System\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-04-18T09:28:07+01:00","created_at":"2019-04-18T12:44:54+01:00","vendor":"Haefely Hipotronics","type":"Electrostatic Discharge Test System","tags":["Discharge Test Systems","EMC","Haefely Hipotronics","Manufacturer_Haefely Hipotronics","Product Type_EMC"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":27934835867726,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ONYX-16","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Haefely Hipotronics ONYX 16 Electrostatic Discharge Test System","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_ONYX_16_Electrostatic_Discharge_Test_System.jpg?v=1562332339","\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_ONYX_16_Electrostatic_Discharge_Test_System_Carry_Case.jpg?v=1562332339"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_ONYX_16_Electrostatic_Discharge_Test_System.jpg?v=1562332339","options":["Title"],"media":[{"alt":"Haefely Hipotronics ONYX 16 Electrostatic Discharge Test System | MCS Rentals","id":1092611866702,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_ONYX_16_Electrostatic_Discharge_Test_System.jpg?v=1562332339"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_ONYX_16_Electrostatic_Discharge_Test_System.jpg?v=1562332339","width":600},{"alt":"Haefely Hipotronics ONYX 16 Electrostatic Discharge Test System | MCS Rentals","id":1184895991886,"position":2,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_ONYX_16_Electrostatic_Discharge_Test_System_Carry_Case.jpg?v=1562332339"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_ONYX_16_Electrostatic_Discharge_Test_System_Carry_Case.jpg?v=1562332339","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHaefely Hipotronics ONYX 16 Electrostatic Discharge Test System Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Haefely Hipotronics ONYX 16 is a state of the art electrostatic discharge simulator available in 16 kV or 30 kV versions. It is the most ergonomic ESD simulator without any additional base control unit that can be battery or mains operated. The easy to use touch screen, ergonomic design, modular RC units, multilingual interface, remote control software, built-in LED light and temperature \u0026amp; humidity display allows for trouble-free use of the ONYX in all types of test sites. The ONYX also includes a bleeder resistor which is connected in parallel with the output of the high-voltage power supply circuit. This ensures that the high voltage power supply is completely discharged after each injected pulse to an EUT or if the ESD simulator itself will be turned-off by the user (bleed-off).\u003cbr\u003e\u003cbr\u003eThe smart key button, integrated into the trigger button has various functions that can be defined by the user including polarity switching, LED light, counter reset, voltage stepping up\/down and others. \u003cbr\u003e\u003cbr\u003eThe ONYX also features a unique self test which verifies all of the main components of the unit are working correctly. This ensures that accurate and reliable tests are performed every time the gun is used.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHaefely Hipotronics ONYX 16 Electrostatic Discharge Test System Specification\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications - Scope of Supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"1\" cellpadding=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir discharge voltage\u003c\/td\u003e\n\u003ctd\u003e1 .. 16 kV or 1 .. 30 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage resolution\u003c\/td\u003e\n\u003ctd\u003e100 V steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCont. discharge voltage\u003c\/td\u003e\n\u003ctd\u003e1 .. 16 kV or 1 .. 30 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge polarity\u003c\/td\u003e\n\u003ctd\u003epositive \u0026amp; negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge repetition\u003c\/td\u003e\n\u003ctd\u003esingle\/0.1\/0.2\/0.5\/1\/2\/5\/10\/20 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating modes\u003c\/td\u003e\n\u003ctd\u003esingle \u0026amp; continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge counter\u003c\/td\u003e\n\u003ctd\u003e1 .. 9999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 16 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault R\/C – network\u003c\/td\u003e\n\u003ctd\u003e150 pF \/ 330 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e17 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e290 x 270 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cbr\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Haefely_Hipotronics_ONYX_16_Electrostatic_Discharge_Test_System_Datasheet.pdf?1020\" title=\"Haefely Hipotronics ONYX 16 Electrostatic Discharge Test System\"\u003eHaefely Hipotronics ONYX 16 Electrostatic Discharge Test System\u003c\/a\u003e\u003c\/p\u003e"}
    Haefely Hipotronics ONYX 16 Electrostatic Discharge Test System Haefely Hipotronics ONYX 16 Electrostatic Discharge Test System
    Haefely Hipotronics ONYX 16 Electrostatic Discharge Test System
    The Haefely Hipotronics ONYX 16 is a state of the art electrostatic discharge simulator available in 16 kV or 30 kV versions. It is the most ergonomic ESD simulator without any additional base control unit that can be battery or mains operated.
    {"id":3496838201422,"title":"Haefely Hipotronics AXOS 8, 7kV Compact Immunity Tester","handle":"haefely-hipotronics-axos-8-compact-immunity-tester","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHaefely Hipotronics AXOS 8, 7kV Compact Immunity Tester Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Haefely Hipotronics AXOS 8 - Compact integrates all of the best features of our stand alone test systems into one single economic solution. It is capable of 5kV EFT\/Burst, 7kV Combination Wave (1.2\/50us \u0026amp; 8\/20us), 7kV Ring Wave, AC\/DC Dips \u0026amp; Interrupts(*), Pulsed Magnetic Field(**), and Telecom Wave(***). \u003cbr\u003e\u003cbr\u003eThe AXOS 8 also includes an integrated single-phase coupling decoupling network (CDN) for EMC testing applications up to 16A.The expandable functionality allows for quick and completely automated testing to the most common IEC, EN, ANSI, IEEE and UL standards. \u003cbr\u003e\u003cbr\u003eThe AXOS 8 unit can either be operated via front panel by large colour graphic interface or remotely from the PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less frequently users. Numerous additional functions such as external start\/stop function allows easy integration of the test system also in customer specific test environments.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to operate with manual and automated test modes, software assisted test preparation, pre-defined test routines and visual aided test setups\u003c\/li\u003e\n\u003cli\u003eEconomic and Efficient: Touch screen guarantees reduction of time and effort - Experience and know-how at a reasonable price\u003c\/li\u003e\n\u003cli\u003eMultiple testing functions available in a single unit\u003c\/li\u003e\n\u003cli\u003eSafe and reliable operation by using safety interlock, warning lamp and emergency stop functions\u003c\/li\u003e\n\u003cli\u003eVoltage and current monitoring of surge impulses and EUT power provides valuable feedback to the test engineer\u003c\/li\u003e\n\u003cli\u003eAutomatic generation of test report, including test parameters, test setup and test result\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet\u003cbr\u003e\u003c\/strong\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Haefely_Hipotronics_AXOS_5kV_Compact_Immunity_Tester_Datasheet.pdf?1019\" title=\"Haefely Hipotronics AXOS 8 7kV Compact Immunity Tester Datasheet\"\u003eHaefely Hipotronics AXOS 8 7kV Compact Immunity Tester Datasheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-04-17T15:19:01+01:00","created_at":"2019-04-17T15:19:01+01:00","vendor":"Haefely Hipotronics","type":"Immunity Tester","tags":["EMC","Haefely Hipotronics","Immunity Testers","Manufacturer_Haefely Hipotronics","Product Type_EMC"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":27927363420238,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AXOS-8","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Haefely Hipotronics AXOS 8, 7kV Compact Immunity Tester","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_AXOS_8_7kV_Compact_Immunity_Tester.jpg?v=1562332339"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_AXOS_8_7kV_Compact_Immunity_Tester.jpg?v=1562332339","options":["Title"],"media":[{"alt":"Haefely Hipotronics AXOS 8, 7kV Compact Immunity Tester | MCS Rentals","id":1090349072462,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_AXOS_8_7kV_Compact_Immunity_Tester.jpg?v=1562332339"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_AXOS_8_7kV_Compact_Immunity_Tester.jpg?v=1562332339","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHaefely Hipotronics AXOS 8, 7kV Compact Immunity Tester Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Haefely Hipotronics AXOS 8 - Compact integrates all of the best features of our stand alone test systems into one single economic solution. It is capable of 5kV EFT\/Burst, 7kV Combination Wave (1.2\/50us \u0026amp; 8\/20us), 7kV Ring Wave, AC\/DC Dips \u0026amp; Interrupts(*), Pulsed Magnetic Field(**), and Telecom Wave(***). \u003cbr\u003e\u003cbr\u003eThe AXOS 8 also includes an integrated single-phase coupling decoupling network (CDN) for EMC testing applications up to 16A.The expandable functionality allows for quick and completely automated testing to the most common IEC, EN, ANSI, IEEE and UL standards. \u003cbr\u003e\u003cbr\u003eThe AXOS 8 unit can either be operated via front panel by large colour graphic interface or remotely from the PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less frequently users. Numerous additional functions such as external start\/stop function allows easy integration of the test system also in customer specific test environments.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to operate with manual and automated test modes, software assisted test preparation, pre-defined test routines and visual aided test setups\u003c\/li\u003e\n\u003cli\u003eEconomic and Efficient: Touch screen guarantees reduction of time and effort - Experience and know-how at a reasonable price\u003c\/li\u003e\n\u003cli\u003eMultiple testing functions available in a single unit\u003c\/li\u003e\n\u003cli\u003eSafe and reliable operation by using safety interlock, warning lamp and emergency stop functions\u003c\/li\u003e\n\u003cli\u003eVoltage and current monitoring of surge impulses and EUT power provides valuable feedback to the test engineer\u003c\/li\u003e\n\u003cli\u003eAutomatic generation of test report, including test parameters, test setup and test result\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet\u003cbr\u003e\u003c\/strong\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Haefely_Hipotronics_AXOS_5kV_Compact_Immunity_Tester_Datasheet.pdf?1019\" title=\"Haefely Hipotronics AXOS 8 7kV Compact Immunity Tester Datasheet\"\u003eHaefely Hipotronics AXOS 8 7kV Compact Immunity Tester Datasheet\u003c\/a\u003e\u003c\/p\u003e"}
    Haefely Hipotronics AXOS 8, 7kV Compact Immunity Tester
    Haefely Hipotronics AXOS 8, 7kV Compact Immunity Tester
    The Haefely Hipotronics AXOS 8 - Compact integrates all of the best features of our stand alone test systems into one single economic solution.
    {"id":3496805761102,"title":"Haefely Hipotronics AXOS 5, 5kV Compact Immunity Tester","handle":"haefely-hipotronics-axos-5-compact-immunity-tester","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHaefely Hipotronics AXOS 5, 5kV Compact Immunity Tester Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Haefely Hiprotronix AXOS 5 EFT\/Burst is a stand-alone 5kV EFT\/Burst Generator with an integrated single phase coupling decoupling network (CDN) for EMC testing applications up to 16A. \u003cbr\u003e\u003cbr\u003eThe AXOS 5 - EFT\/Burst can also be capable of performing 5kV Surge Combination Wave (1.2\/50us \u0026amp; 8\/20us), AC\/DC Voltage Dips and Pulsed Magnetic Field tests via software and\/or hardware upgrades.The expandable functionality allows for quick and completely automated testing to the most common IEC, EN, ANSI, IEEE and UL standards. \u003cbr\u003e\u003cbr\u003eThe Haefely Hipotronicx AXOS 5 unit can either be operated via front panel by large colour graphic interface or remotely from the PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less frequently users. Numerous additional functions such as external start\/stop function allows easy integration of the test system also in customer specific test environments. Easy to operate with manual and automated test modes, software assisted test preparation, pre-defined test routines and visual aided test setups.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEconomic and Efficient Touch screen guarantees reduction of time and effort - Experience and know-how at a reasonable price\u003c\/li\u003e\n\u003cli\u003eSafe and reliable operation by using safety interlock, warning lamp and emergency stop functions\u003c\/li\u003e\n\u003cli\u003eVoltage and current monitoring of surge impulses and EUT power provides valuable feedback to the test engineer\u003c\/li\u003e\n\u003cli\u003eAutomatic generation of test report, including test parameters, test setup and test result\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHaefely Hipotronics AXOS 5 Specification\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"text_three\"\u003e\n\u003ctable class=\"table table-striped table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85V - 264V, 50\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e(W X H X D)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e19\"\/4U - 45 x 18 x 49 cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Test Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnlimited\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet, RJ45\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor USB memory stick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e7\" 800 x 480 \/ 24 bit with touch screen\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAUX interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eD-SUB 37 pin for external CDN, External transformer, other.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Trigger Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V TTL\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSynch Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBNC, 10V - 264V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V TTL\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal start\/stop input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V TTL, Starts\/stops predefined test sequence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUT failed input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V TTL\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 10V, for use with external options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarning Lamp Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x 24V \/ 1A DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStops the test when unlocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"text_four\"\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cbr\u003eIEC\/EN 61000-4-4 Edition 3 EFT\/Bursts\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"table table-striped table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.2 - 5.0kV ± 10%\u003c\/p\u003e\n\u003cp\u003eat coaxial output\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpike Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1Hz - 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePolarity \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive \/ Negative \/ Alternate\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10μs - 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50Ω\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst Period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1ms - 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5ns ± 30%\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1s - 1000 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e50ns ± 30% at 50Ω,\u003c\/p\u003e\n\u003cp\u003e50ns -15 + 100ns at 100Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, or External Trigger Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNormal, Continuous, Real, Random\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated single phase coupling \/ decoupling network\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e264V AC \/ 16A\u003c\/p\u003e\n\u003cp\u003e220V DC \/ 10A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cbr\u003eIEC\/EN 61000-4-5 Edition 3 Surge Combination Wave\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"table table-striped table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 - 5kV ± 10%\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 - 2.5kA ± 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2μs ± 30%\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8μs ± 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50μs ± 20%\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20μs ± 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePolarity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive \/ Negative \/ Alternate\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated Single Phase Coupling \/ Decoupling Network\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e264V AC \/ 16A\u003c\/p\u003e\n\u003cp\u003e220V DC \/ 10A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2Ω \/ 12Ω\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Trigger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic 2s - 100 min\u003c\/p\u003e\n\u003cp\u003emanual\u003c\/p\u003e\n\u003cp\u003eexternal trigger input\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCounter Preset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 - 1000 \/ infinite\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBNC output: 1kA\/V\u003c\/p\u003e\n\u003cp\u003eDisplay: 3 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCounter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Voltage Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBNC output 1000:1\u003c\/p\u003e\n\u003cp\u003eDisplay: 3 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"text_five\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text_five\"\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cbr\u003eIEC\/EN 61000-4-11 Edition 2 and IEC\/EN 61000-4-29 Dips and Interrupts\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"table table-striped table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Voltage*\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e264V AC\u003c\/p\u003e\n\u003cp\u003e220V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.5 - 800 periods\u003c\/p\u003e\n\u003cp\u003e100μs - 1000 min\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax current*\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10A DC\u003c\/p\u003e\n\u003cp\u003e16A AC Continuous\u003c\/p\u003e\n\u003cp\u003e20A for 5s\u003c\/p\u003e\n\u003cp\u003e23A for 3s\u003c\/p\u003e\n\u003cp\u003e40A for 3s\u003c\/p\u003e\n\u003cp\u003e\u0026gt;500A inrush current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInterval Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 - 800 period synchcronous\u003c\/p\u003e\n\u003cp\u003e100μs - 1000 min asynchronous\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003cp\u003eManual\u003c\/p\u003e\n\u003cp\u003eExternal Trigger input\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1s - 1000 min\u003c\/p\u003e\n\u003cp\u003eInfinite\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eInterrupt Level\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDip Level\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0%\u003c\/p\u003e\n\u003cp\u003e0-99% with External Voltage Source\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Sync\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-359º 16\/40\/50\/60Hz\u003c\/p\u003e\n\u003cp\u003eAsynchronous Mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRMS Voltage Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBNC output: 100:1\u003c\/p\u003e\n\u003cp\u003eDisplay: 4 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRMS Current Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBNC output: 10A\/V\u003c\/p\u003e\n\u003cp\u003eDisplay: 4 digitis\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e*AC power only for AXOS unit. Do not use DC through DIP 116 unit\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Haefely_Hipotronics_AXOS_5kV_Compact_Immunity_Tester_Datasheet.pdf?1019\" title=\"Haefely Hipotronics AXOS 5 5kV Compact Immunity Tester Datasheet\"\u003eHaefely Hipotronics AXOS 5 5kV Compact Immunity Tester Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","published_at":"2019-04-17T14:24:41+01:00","created_at":"2019-04-17T14:46:56+01:00","vendor":"Haefely Hipotronics","type":"Immunity Tester","tags":["EMC","Haefely Hipotronics","Immunity Testers","Manufacturer_Haefely Hipotronics","Product Type_EMC"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":27927278354510,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AXOS-5","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Haefely Hipotronics AXOS 5, 5kV Compact Immunity Tester","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_AXOS_5kV_Compact_Immunity_Tester.jpg?v=1562332338"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_AXOS_5kV_Compact_Immunity_Tester.jpg?v=1562332338","options":["Title"],"media":[{"alt":"Haefely Hipotronics AXOS 5, 5kV Compact Immunity Tester | MCS Rentals","id":1090257879118,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_AXOS_5kV_Compact_Immunity_Tester.jpg?v=1562332338"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/Haefely_Hipotronics_AXOS_5kV_Compact_Immunity_Tester.jpg?v=1562332338","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHaefely Hipotronics AXOS 5, 5kV Compact Immunity Tester Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Haefely Hiprotronix AXOS 5 EFT\/Burst is a stand-alone 5kV EFT\/Burst Generator with an integrated single phase coupling decoupling network (CDN) for EMC testing applications up to 16A. \u003cbr\u003e\u003cbr\u003eThe AXOS 5 - EFT\/Burst can also be capable of performing 5kV Surge Combination Wave (1.2\/50us \u0026amp; 8\/20us), AC\/DC Voltage Dips and Pulsed Magnetic Field tests via software and\/or hardware upgrades.The expandable functionality allows for quick and completely automated testing to the most common IEC, EN, ANSI, IEEE and UL standards. \u003cbr\u003e\u003cbr\u003eThe Haefely Hipotronicx AXOS 5 unit can either be operated via front panel by large colour graphic interface or remotely from the PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less frequently users. Numerous additional functions such as external start\/stop function allows easy integration of the test system also in customer specific test environments. Easy to operate with manual and automated test modes, software assisted test preparation, pre-defined test routines and visual aided test setups.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEconomic and Efficient Touch screen guarantees reduction of time and effort - Experience and know-how at a reasonable price\u003c\/li\u003e\n\u003cli\u003eSafe and reliable operation by using safety interlock, warning lamp and emergency stop functions\u003c\/li\u003e\n\u003cli\u003eVoltage and current monitoring of surge impulses and EUT power provides valuable feedback to the test engineer\u003c\/li\u003e\n\u003cli\u003eAutomatic generation of test report, including test parameters, test setup and test result\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHaefely Hipotronics AXOS 5 Specification\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"text_three\"\u003e\n\u003ctable class=\"table table-striped table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85V - 264V, 50\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e(W X H X D)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e19\"\/4U - 45 x 18 x 49 cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Test Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnlimited\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet, RJ45\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor USB memory stick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e7\" 800 x 480 \/ 24 bit with touch screen\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAUX interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eD-SUB 37 pin for external CDN, External transformer, other.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Trigger Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V TTL\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSynch Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBNC, 10V - 264V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V TTL\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal start\/stop input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V TTL, Starts\/stops predefined test sequence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUT failed input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V TTL\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 10V, for use with external options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarning Lamp Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x 24V \/ 1A DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStops the test when unlocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"text_four\"\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cbr\u003eIEC\/EN 61000-4-4 Edition 3 EFT\/Bursts\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"table table-striped table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.2 - 5.0kV ± 10%\u003c\/p\u003e\n\u003cp\u003eat coaxial output\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpike Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1Hz - 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePolarity \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive \/ Negative \/ Alternate\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10μs - 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50Ω\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst Period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1ms - 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5ns ± 30%\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1s - 1000 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e50ns ± 30% at 50Ω,\u003c\/p\u003e\n\u003cp\u003e50ns -15 + 100ns at 100Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, or External Trigger Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNormal, Continuous, Real, Random\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated single phase coupling \/ decoupling network\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e264V AC \/ 16A\u003c\/p\u003e\n\u003cp\u003e220V DC \/ 10A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cbr\u003eIEC\/EN 61000-4-5 Edition 3 Surge Combination Wave\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"table table-striped table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 - 5kV ± 10%\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 - 2.5kA ± 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2μs ± 30%\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8μs ± 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50μs ± 20%\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20μs ± 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePolarity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive \/ Negative \/ Alternate\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated Single Phase Coupling \/ Decoupling Network\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e264V AC \/ 16A\u003c\/p\u003e\n\u003cp\u003e220V DC \/ 10A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2Ω \/ 12Ω\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Trigger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic 2s - 100 min\u003c\/p\u003e\n\u003cp\u003emanual\u003c\/p\u003e\n\u003cp\u003eexternal trigger input\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCounter Preset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 - 1000 \/ infinite\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBNC output: 1kA\/V\u003c\/p\u003e\n\u003cp\u003eDisplay: 3 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCounter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Voltage Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBNC output 1000:1\u003c\/p\u003e\n\u003cp\u003eDisplay: 3 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"text_five\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text_five\"\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cbr\u003eIEC\/EN 61000-4-11 Edition 2 and IEC\/EN 61000-4-29 Dips and Interrupts\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"table table-striped table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Voltage*\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e264V AC\u003c\/p\u003e\n\u003cp\u003e220V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.5 - 800 periods\u003c\/p\u003e\n\u003cp\u003e100μs - 1000 min\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax current*\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10A DC\u003c\/p\u003e\n\u003cp\u003e16A AC Continuous\u003c\/p\u003e\n\u003cp\u003e20A for 5s\u003c\/p\u003e\n\u003cp\u003e23A for 3s\u003c\/p\u003e\n\u003cp\u003e40A for 3s\u003c\/p\u003e\n\u003cp\u003e\u0026gt;500A inrush current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInterval Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 - 800 period synchcronous\u003c\/p\u003e\n\u003cp\u003e100μs - 1000 min asynchronous\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003cp\u003eManual\u003c\/p\u003e\n\u003cp\u003eExternal Trigger input\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1s - 1000 min\u003c\/p\u003e\n\u003cp\u003eInfinite\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eInterrupt Level\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDip Level\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0%\u003c\/p\u003e\n\u003cp\u003e0-99% with External Voltage Source\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Sync\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-359º 16\/40\/50\/60Hz\u003c\/p\u003e\n\u003cp\u003eAsynchronous Mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRMS Voltage Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBNC output: 100:1\u003c\/p\u003e\n\u003cp\u003eDisplay: 4 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRMS Current Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBNC output: 10A\/V\u003c\/p\u003e\n\u003cp\u003eDisplay: 4 digitis\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e*AC power only for AXOS unit. Do not use DC through DIP 116 unit\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Haefely_Hipotronics_AXOS_5kV_Compact_Immunity_Tester_Datasheet.pdf?1019\" title=\"Haefely Hipotronics AXOS 5 5kV Compact Immunity Tester Datasheet\"\u003eHaefely Hipotronics AXOS 5 5kV Compact Immunity Tester Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e"}
    Haefely Hipotronics AXOS 5, 5kV Compact Immunity Tester
    Haefely Hipotronics AXOS 5, 5kV Compact Immunity Tester
    The Haefely Hiprotronix AXOS 5 5kV EFT/Burst is a stand-alone 5kV EFT/Burst Generator with an integrated single phase coupling decoupling network (CDN) for EMC testing applications up to 16A.
    {"id":3525725847630,"title":"Compliance West HT-5000P V2 Hipot Tester 0-5000Vac @ 10mA \/ 0-6000Vdc @ 5mA Rugged","handle":"compliance-west-ht-5000p-v2-hipot-tester","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eCompliance West HT-5000P V2 Hipot Tester Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Compliance West HT-5000P V2 has a rugged design with easy-to-use Microcontroller Technology, this AC\/DC hipot tests to 5,000Vac @ 10mA and 6,000Vdc @ 5mA. Tested to withstand a 6\" drop test with no damage. Made in the USA.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eCompliance West HT-5000P Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC output: up to 5,000 V.\u003c\/li\u003e\n\u003cli\u003eDC output: up to 6,000 V.\u003c\/li\u003e\n\u003cli\u003eMicrocontroller Technology, one button test, easy to set up.\u003c\/li\u003e\n\u003cli\u003eLED's indicate test progress. Upon failure, buzzer sounds and testing is terminated.\u003c\/li\u003e\n\u003cli\u003eLeakage current limit, voltage ramp-up time and test duration are controlled from the rear panel.\u003c\/li\u003e\n\u003cli\u003eVoltage ramp, arc detection and test timer are defeatable.\u003c\/li\u003e\n\u003cli\u003eSeparate arc detection circuitry.\u003c\/li\u003e\n\u003cli\u003eErgonomically designed for safety, speed and efficiency.\u003c\/li\u003e\n\u003cli\u003eDesigned for product development, production and laboratory use.\u003c\/li\u003e\n\u003cli\u003eRugged construction that can withstand a 6” drop with no damage.\u003c\/li\u003e\n\u003cli\u003eCables, manual and calibration certificate included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eCompliance West HT-5000P V2 Hipot Tester Specification\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellspacing=\"1\" cellpadding=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Test Type\u003c\/td\u003e\n\u003ctd\u003eAC\/DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e0-5000 AC 0-6000 DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e1-10 mA AC 1-5 m A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Requirements\u003c\/td\u003e\n\u003ctd\u003e117-127 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Requirements\u003c\/td\u003e\n\u003ctd\u003eSee Rear Panel for Correct Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArc Detect\u003c\/td\u003e\n\u003ctd\u003eSeparate High Frequency Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Detect\u003c\/td\u003e\n\u003ctd\u003eSeparate Low Frequency Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Time Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 - 60 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRamp time Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 - 5 Seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Meter Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" class=\"spectable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelldata\"\u003e± 2 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDuty cycle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDischarge Time (Resistive Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Set 8 Sec max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTransformer Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 500 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePass\/Fail Repeatability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 3 %\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput connector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Voltage Jack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 digits LED display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLed indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFailure Indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLed indicators and buzzer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC Interface\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTestLink\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTestminder\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Hold on failure\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Defeat\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-Ramp Time\u003cbr\u003e-Test Time\u003cbr\u003e-Breakdown Detect\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoreset on Pass\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e Optional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 - 40 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity Range\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 90 % Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\" wide x 5\" high x 12\" deep\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17.5 Lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Cords\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReturn lead\u003cbr\u003eHigh Voltage Test Lead\u003cbr\u003ePower cord\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/HT-5000P_V2_Datasheet.pdf?1050\" title=\"HT-5000P V2 Hipot Tester Datasheet\"\u003eHT-5000P V2 Hipot Tester Datasheet\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eManual\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/HT-5000P_V2_Manual.pdf?1050\" title=\"HT-5000P V2 Hipot Tester Manual\"\u003eHT-5000P V2 Hipot Tester Manual\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-04-23T10:43:15+01:00","created_at":"2019-04-23T10:47:17+01:00","vendor":"Compliance West","type":"Hipot Tester","tags":["Compliance West","EMC","Hipot Testers","Manufacturer_Compliance West","Product Type_EMC"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":28049331388494,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HT-5000P V2","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Compliance West HT-5000P V2 Hipot Tester 0-5000Vac @ 10mA \/ 0-6000Vdc @ 5mA Rugged","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/HT-5000P_V2.jpg?v=1562332336"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/HT-5000P_V2.jpg?v=1562332336","options":["Title"],"media":[{"alt":"Compliance West HT-5000P V2 Hipot Tester 0-5000Vac @ 10mA \/ 0-6000Vdc @ 5mA Rugged | MCS Rentals","id":1105029759054,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/HT-5000P_V2.jpg?v=1562332336"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/HT-5000P_V2.jpg?v=1562332336","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eCompliance West HT-5000P V2 Hipot Tester Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Compliance West HT-5000P V2 has a rugged design with easy-to-use Microcontroller Technology, this AC\/DC hipot tests to 5,000Vac @ 10mA and 6,000Vdc @ 5mA. Tested to withstand a 6\" drop test with no damage. Made in the USA.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eCompliance West HT-5000P Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC output: up to 5,000 V.\u003c\/li\u003e\n\u003cli\u003eDC output: up to 6,000 V.\u003c\/li\u003e\n\u003cli\u003eMicrocontroller Technology, one button test, easy to set up.\u003c\/li\u003e\n\u003cli\u003eLED's indicate test progress. Upon failure, buzzer sounds and testing is terminated.\u003c\/li\u003e\n\u003cli\u003eLeakage current limit, voltage ramp-up time and test duration are controlled from the rear panel.\u003c\/li\u003e\n\u003cli\u003eVoltage ramp, arc detection and test timer are defeatable.\u003c\/li\u003e\n\u003cli\u003eSeparate arc detection circuitry.\u003c\/li\u003e\n\u003cli\u003eErgonomically designed for safety, speed and efficiency.\u003c\/li\u003e\n\u003cli\u003eDesigned for product development, production and laboratory use.\u003c\/li\u003e\n\u003cli\u003eRugged construction that can withstand a 6” drop with no damage.\u003c\/li\u003e\n\u003cli\u003eCables, manual and calibration certificate included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eCompliance West HT-5000P V2 Hipot Tester Specification\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellspacing=\"1\" cellpadding=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Test Type\u003c\/td\u003e\n\u003ctd\u003eAC\/DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e0-5000 AC 0-6000 DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e1-10 mA AC 1-5 m A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Requirements\u003c\/td\u003e\n\u003ctd\u003e117-127 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Requirements\u003c\/td\u003e\n\u003ctd\u003eSee Rear Panel for Correct Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArc Detect\u003c\/td\u003e\n\u003ctd\u003eSeparate High Frequency Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Detect\u003c\/td\u003e\n\u003ctd\u003eSeparate Low Frequency Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Time Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 - 60 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRamp time Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 - 5 Seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Meter Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" class=\"spectable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelldata\"\u003e± 2 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDuty cycle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDischarge Time (Resistive Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Set 8 Sec max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTransformer Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 500 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePass\/Fail Repeatability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 3 %\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput connector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Voltage Jack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 digits LED display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLed indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFailure Indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLed indicators and buzzer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC Interface\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTestLink\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTestminder\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Hold on failure\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Defeat\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-Ramp Time\u003cbr\u003e-Test Time\u003cbr\u003e-Breakdown Detect\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoreset on Pass\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e Optional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 - 40 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity Range\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 90 % Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\" wide x 5\" high x 12\" deep\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17.5 Lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Cords\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReturn lead\u003cbr\u003eHigh Voltage Test Lead\u003cbr\u003ePower cord\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/HT-5000P_V2_Datasheet.pdf?1050\" title=\"HT-5000P V2 Hipot Tester Datasheet\"\u003eHT-5000P V2 Hipot Tester Datasheet\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eManual\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/HT-5000P_V2_Manual.pdf?1050\" title=\"HT-5000P V2 Hipot Tester Manual\"\u003eHT-5000P V2 Hipot Tester Manual\u003c\/a\u003e\u003c\/p\u003e"}
    Compliance West HT-5000P V2 Hipot Tester 0-5000Vac @ 10mA / 0-6000Vdc @ 5mA Rugged
    Compliance West HT-5000P V2 Hipot Tester 0-5000Vac @ 10mA / 0-6000Vdc @ 5mA Rugged
    The Compliance West HT-5000P V2 has a rugged design with easy-to-use Microcontroller Technology, this AC/DC hipot tests to 5,000Vac @ 10mA and 6,000Vdc @ 5mA.
    MCS Rentals
    Address: MCS Rentals, Glascoed Road,
    New Vision Business Park,
    St Asaph, Denbighshire.
    LL17 0LP
    Mon - Fri: 09:00 - 17:00 Phone: 01492 643 060
    Email: sales@mcsrentals.com
    Follow us on:
    • About us
    • Contact us
    • Privacy Policy
    • Terms & Conditions

    Registered in England & Wales
    Copyright © 2023 MCS Rentals Ltd
    Registered Company Number: 04147703

      Sample Product

      • Twitter
      • Facebook
      • Google+