Your Cart
Menu
  • Product Groups
    • Antenna Alignment
    • Aviation
    • Cable & Antenna Analysers
    • Calibration Kits
    • EMC
    • Meters
    • Network Analysers
    • Optical Test Equipment
    • Oscilloscopes
    • PIM Masters
    • Power Sensors
    • Power Supplies
    • RF Amplifiers
    • Safety Monitors
    • RF Shielded Boxes
    • Signal / Spectrum Analysers
    • Signal Generators
    • Temperature
    • Wireless Testers
  • Manufacturers
    • 3Z Telecom
    • Amplifier Research
    • Anritsu
    • Compliance West
    • EXFO
    • FieldSENSE
    • Fluke
    • Haefely Hipotronics
    • Keysight
    • Litepoint
    • Megger
    • Narda STS
    • Rohde & Schwarz
    • ShinewayTech
    • Sunsight Instruments
    • Tektronix
    • Tescom
    • Viavi
    • Vötsch
  • About us
  • Looking to Buy New?
  • Calibration
  • Components
  • Contact
MCS Rentals
    Customer Login Phone: 01492 643 060
    Email: sales@mcsrentals.com
    Menu
    MCS Rentals
    MCS Rentals
    • Product Groups
      • Antenna Alignment
      • Aviation
      • Cable & Antenna Analysers
      • Calibration Kits
      • EMC
      • Meters
      • Network Analysers
      • Optical Test Equipment
      • Oscilloscopes
      • PIM Masters
      • Power Sensors
      • Power Supplies
      • RF Amplifiers
      • Safety Monitors
      • RF Shielded Boxes
      • Signal / Spectrum Analysers
      • Signal Generators
      • Temperature
      • Wireless Testers
    • Manufacturers
      • 3Z Telecom
      • Amplifier Research
      • Anritsu
      • Compliance West
      • EXFO
      • FieldSENSE
      • Fluke
      • Haefely Hipotronics
      • Keysight
      • Litepoint
      • Megger
      • Narda STS
      • Rohde & Schwarz
      • ShinewayTech
      • Sunsight Instruments
      • Tektronix
      • Tescom
      • Viavi
      • Vötsch
    • About us
    • Looking to Buy New?
    • Calibration
    • Components
    • Contact
    Shop Departments
    • 3Z Telecom
    • Amplifier Research
    • Anritsu
      • Antenna Analysers
      • Cable Analysers
      • PIM Masters
      • Site Masters
    • Fluke Networks
    • Haefely Hipotronics
    • LitePoint
    • Keysight Technologies
    • Narda STS
    • Rohde & Schwarz
      • Network Analysers
      • Power Sensors
      • Spectrum Analysers
      • Signal Generators
    • ShinewayTech
    • Sunsight Instruments
    • Tektronix
    • Tescom
    • Viavi
    • MCS RentalsHome
    • Rohde & Schwarz Network Analysers
    • Rohde & Schwarz Network Analysers
    Latest Products
    Rohde & Schwarz CBT Bluetooth Tester | MCS Rentals
    Rohde & Schwarz CBT Bluetooth Tester
    $0.00
    Rohde & Schwarz CMW-Z10 RF Shield Box | MCS Rentals
    Rohde & Schwarz CMW-Z10 RF Shield Box
    $0.00
    Rohde & Schwarz CMW290 Functional Communications Tester | MCS Rentals
    Rohde & Schwarz CMW290 Functional Communications Tester
    $0.00
    Rohde & Schwarz CMW500 Wideband Communications Tester | MCS Rentals
    Rohde & Schwarz CMW500 Wideband Communications Tester
    $0.00
    LitePoint IQcell Multi-Device Signalling Test Solution | MCS Rentals
    LitePoint IQcell Multi-Device Signalling Test Solution
    $0.00
    Narda STS Nardalert S3 Personal Radiation Monitor | MCS Rentals
    Narda STS Nardalert S3 Personal Radiation Monitor
    $0.00

    Rohde & Schwarz Network Analysers

    Rohde & Schwarz Network Analysers

    {"id":3550934106190,"title":"Rohde \u0026 Schwarz ZVB8 Vector Network Analyser","handle":"rohde-schwarz-zvb8-vector-network-analyser","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVB8 Vector Network Analyser Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003ca href=\"https:\/\/www.mcsrentals.com\/collections\/rohde-schwarz\" title=\"Rohde \u0026amp; Schwarz Test Equipment\"\u003eRohde \u0026amp; Schwarz\u003c\/a\u003e ZVB8 combines excellent performance with low weight and compact design. Intelligent and user-friendly functions offer maximum ease of operation. They allow the large number of measured quantities involved in multi port and balanced measurements to be handled easily, and also offer a variety of ways to optimise production sequences – a smart solution that satisfies even the most challenging demands.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003e Rohde \u0026amp; Schwarz ZVB8 Features \u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cli\u003eMedium-class network analyser featuring outstanding performance\u003c\/li\u003e\n\u003cli\u003e300 kHz to 8 GHz\u003c\/li\u003e\n\u003cli\u003eOver range up to 150 kHz (unspecified and without calibration ex factory)\u003c\/li\u003e\n\u003cli\u003eCapable of balanced measurements (mixed-mode S-parameters)\u003c\/li\u003e\n\u003cli\u003eInternal step attenuators available as options (up to two attenuators can be installed; for details click link to respective option)\u003c\/li\u003e\n\u003cli\u003eTwo internal sources (e.g. to provide the RF and LO signals for mixer measurements from a single unit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet\u003cbr\u003e\u003c\/strong\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Rohde_Schwarz_ZVB8_Data_Sheet.pdf?1713\" title=\"Rohde \u0026amp; Schwarz ZVB Vector Network Analyser Datasheet\"\u003eRohde \u0026amp; Schwarz ZVB Vector Network Analyser Datasheet\u003c\/a\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e","published_at":"2019-05-10T12:24:10+01:00","created_at":"2019-05-10T13:41:22+01:00","vendor":"Rohde \u0026 Schwarz","type":"Network Analyser","tags":["Manufacturer_Rohde \u0026 Schwarz","Network Analysers","Product Type_Network Analyser","Rohde \u0026 Schwarz"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":28171433246798,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ZVB8","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Rohde \u0026 Schwarz ZVB8 Vector Network Analyser","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVB.jpg?v=1562332374"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVB.jpg?v=1562332374","options":["Title"],"media":[{"alt":"Rohde \u0026 Schwarz ZVB8 Vector Network Analyser, 300 kHz - 8 GHz | MCS Rentals","id":1153603698766,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVB.jpg?v=1562332374"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVB.jpg?v=1562332374","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVB8 Vector Network Analyser Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003ca href=\"https:\/\/www.mcsrentals.com\/collections\/rohde-schwarz\" title=\"Rohde \u0026amp; Schwarz Test Equipment\"\u003eRohde \u0026amp; Schwarz\u003c\/a\u003e ZVB8 combines excellent performance with low weight and compact design. Intelligent and user-friendly functions offer maximum ease of operation. They allow the large number of measured quantities involved in multi port and balanced measurements to be handled easily, and also offer a variety of ways to optimise production sequences – a smart solution that satisfies even the most challenging demands.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003e Rohde \u0026amp; Schwarz ZVB8 Features \u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cli\u003eMedium-class network analyser featuring outstanding performance\u003c\/li\u003e\n\u003cli\u003e300 kHz to 8 GHz\u003c\/li\u003e\n\u003cli\u003eOver range up to 150 kHz (unspecified and without calibration ex factory)\u003c\/li\u003e\n\u003cli\u003eCapable of balanced measurements (mixed-mode S-parameters)\u003c\/li\u003e\n\u003cli\u003eInternal step attenuators available as options (up to two attenuators can be installed; for details click link to respective option)\u003c\/li\u003e\n\u003cli\u003eTwo internal sources (e.g. to provide the RF and LO signals for mixer measurements from a single unit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet\u003cbr\u003e\u003c\/strong\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Rohde_Schwarz_ZVB8_Data_Sheet.pdf?1713\" title=\"Rohde \u0026amp; Schwarz ZVB Vector Network Analyser Datasheet\"\u003eRohde \u0026amp; Schwarz ZVB Vector Network Analyser Datasheet\u003c\/a\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e"}
    Rohde & Schwarz ZVB8 Vector Network Analyser
    Rohde & Schwarz ZVB8 Vector Network Analyser

    Up to 8 GHz Model Available


    The Rohde & Schwarz ZVB8 combines excellent performance with low weight and compact design. Intelligent and user-friendly functions offer maximum ease of operation.
    {"id":3550964383822,"title":"Rohde \u0026 Schwarz ZVL3 Vector Network Analyser","handle":"rohde-schwarz-zvl3-vector-network-analyser","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVL3 Vector Network Analyser Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Rohde \u0026amp; Schwarz ZVL3 is a compact, powerful, and future-proof network analyser, and is therefore ideal for use in development, production and service. It is the only instrument to combine the functions of a network analyser, spectrum analyser, and power meter in a single box, and will thus tremendously increase your work efficiency\u003cbr\u003e\u003cbr\u003eThe Rohde \u0026amp; Schwarz ZVL3 is ideal for lab applications where the measurement tasks vary frequently; it can be used to measure S-parameters as well as the output spectrum, ACP, and TOI without having to reconnect the device under test (DUT). With the ¸ZVL, production lines can now be run even more flexibly, as the switch over from network analyser to spectrum analyser can easily be effected via remote control. Moreover, an¸ NRP-Z power sensor, which can be directly connected to the ZVL, ensures precise power measurements.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVL3 Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cli\u003eSpecified frequency range 9 kHz to 3 GHz\u003c\/li\u003e\n\u003cli\u003eFrequency over range (unspecified): 5 kHz to 3 GHz\u003c\/li\u003e\n\u003cli\u003eImproved trace noise characteristics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e\u003c\/strong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVL_Vector_Network_Analyser_-_Specifications.pdf?1721\" title=\"R\u0026amp;S ZVL Vector Network Analyser - Specifications\"\u003eR\u0026amp;S ZVL Vector Network Analyser - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-ZCAN_Calibration_Kit_-_Specifications.pdf?1725\" title=\"R\u0026amp;S ZV-ZCAN Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-ZCAN Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_FS-K112PC_NFC_Measurement_Software_-_Specifications.pdf?1725\" title=\"R\u0026amp;S FS-K112PC NFC Measurement Software - Specifications\"\u003eR\u0026amp;S FS-K112PC NFC Measurement Software - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z170_Calibration_Kit_-_Specifications.pdf?1725\" title=\"R\u0026amp;S ZV-Z170 Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-Z170 Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z9x_ZV-Z19x_Test_Port_Cables_-_Specifications.pdf?1725\" title=\"R\u0026amp;S ZV-Z9x, ZV-Z19x Test Port Cables - Specifications\"\u003eR\u0026amp;S ZV-Z9x, ZV-Z19x Test Port Cables - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eProduct Brochures\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-ZCAN_Calibration_Kit_-_Product_Brochure.pdf?1725\" title=\"R\u0026amp;S ZV-ZCAN Calibration Kit - Product Brochure\"\u003eR\u0026amp;S ZV-ZCAN Calibration Kit - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_FS-K112PC_NFC_Measurement_Software_-_Product_Brochure.pdf?1725\" title=\"R\u0026amp;S FS-K112PC NFC Measurement Software - Product Brochure\"\u003eR\u0026amp;S FS-K112PC NFC Measurement Software - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVL_Vector_Network_Analyzer_-_Product_Brochure.pdf?1725\" title=\"R\u0026amp;S ZVL Vector Network Analyzer - Product Brochure\"\u003eR\u0026amp;S ZVL Vector Network Analyzer - Product Brochure\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-05-10T13:45:08+01:00","created_at":"2019-05-10T14:37:22+01:00","vendor":"Rohde \u0026 Schwarz","type":"Network Analyser","tags":["Manufacturer_Rohde \u0026 Schwarz","Network Analysers","Product Type_Network Analyser","Rohde \u0026 Schwarz"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":29135849062478,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ZVL3","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Rohde \u0026 Schwarz ZVL3 Vector Network Analyser","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVL3.jpg?v=1562332375"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVL3.jpg?v=1562332375","options":["Title"],"media":[{"alt":"Rohde \u0026 Schwarz ZVL3 Vector Network Analyser, 8.5 GHz | MCS Rentals","id":1153695154254,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVL3.jpg?v=1562332375"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVL3.jpg?v=1562332375","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVL3 Vector Network Analyser Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Rohde \u0026amp; Schwarz ZVL3 is a compact, powerful, and future-proof network analyser, and is therefore ideal for use in development, production and service. It is the only instrument to combine the functions of a network analyser, spectrum analyser, and power meter in a single box, and will thus tremendously increase your work efficiency\u003cbr\u003e\u003cbr\u003eThe Rohde \u0026amp; Schwarz ZVL3 is ideal for lab applications where the measurement tasks vary frequently; it can be used to measure S-parameters as well as the output spectrum, ACP, and TOI without having to reconnect the device under test (DUT). With the ¸ZVL, production lines can now be run even more flexibly, as the switch over from network analyser to spectrum analyser can easily be effected via remote control. Moreover, an¸ NRP-Z power sensor, which can be directly connected to the ZVL, ensures precise power measurements.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVL3 Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cli\u003eSpecified frequency range 9 kHz to 3 GHz\u003c\/li\u003e\n\u003cli\u003eFrequency over range (unspecified): 5 kHz to 3 GHz\u003c\/li\u003e\n\u003cli\u003eImproved trace noise characteristics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e\u003c\/strong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVL_Vector_Network_Analyser_-_Specifications.pdf?1721\" title=\"R\u0026amp;S ZVL Vector Network Analyser - Specifications\"\u003eR\u0026amp;S ZVL Vector Network Analyser - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-ZCAN_Calibration_Kit_-_Specifications.pdf?1725\" title=\"R\u0026amp;S ZV-ZCAN Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-ZCAN Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_FS-K112PC_NFC_Measurement_Software_-_Specifications.pdf?1725\" title=\"R\u0026amp;S FS-K112PC NFC Measurement Software - Specifications\"\u003eR\u0026amp;S FS-K112PC NFC Measurement Software - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z170_Calibration_Kit_-_Specifications.pdf?1725\" title=\"R\u0026amp;S ZV-Z170 Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-Z170 Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z9x_ZV-Z19x_Test_Port_Cables_-_Specifications.pdf?1725\" title=\"R\u0026amp;S ZV-Z9x, ZV-Z19x Test Port Cables - Specifications\"\u003eR\u0026amp;S ZV-Z9x, ZV-Z19x Test Port Cables - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eProduct Brochures\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-ZCAN_Calibration_Kit_-_Product_Brochure.pdf?1725\" title=\"R\u0026amp;S ZV-ZCAN Calibration Kit - Product Brochure\"\u003eR\u0026amp;S ZV-ZCAN Calibration Kit - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_FS-K112PC_NFC_Measurement_Software_-_Product_Brochure.pdf?1725\" title=\"R\u0026amp;S FS-K112PC NFC Measurement Software - Product Brochure\"\u003eR\u0026amp;S FS-K112PC NFC Measurement Software - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVL_Vector_Network_Analyzer_-_Product_Brochure.pdf?1725\" title=\"R\u0026amp;S ZVL Vector Network Analyzer - Product Brochure\"\u003eR\u0026amp;S ZVL Vector Network Analyzer - Product Brochure\u003c\/a\u003e\u003c\/p\u003e"}
    Rohde & Schwarz ZVL3 Vector Network Analyser
    Rohde & Schwarz ZVL3 Vector Network Analyser

    Up to 3 GHz Model Available


    The Rohde & Schwarz ZVL3 is a compact, powerful, and future-proof network analyser, and is therefore ideal for use in development, production and service.
    {"id":3550975328334,"title":"Rohde \u0026 Schwarz ZVM Vector Network Analyser","handle":"rohde-schwarz-zvm-vector-network-analyser","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVM Vector Network Analyser Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Rohde \u0026amp; Schwarz ZVM extend the frequency range of the Rohde \u0026amp; network analysers to 20 GHz. The outstanding performance in terms of speed, dynamic range and accuracy makes it ideal for applications such as S-parameter or group delay measurements. This is enhanced by a wealth of measurement, display and logging functions. In addition, ZVM can be used for complex measurement tasks, such as measurements on frequency-converting DUTs (conversion loss, inter modulation, spurious) and nonlinear measurements (intercept point and compression point).\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVM Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExcellent dynamic range\u003c\/li\u003e\n\u003cli\u003e\u0026gt;115 dB (measurement bandwidth 10 Hz)\u003c\/li\u003e\n\u003cli\u003eLow inherent noise\u003c\/li\u003e\n\u003cli\u003e\u0026lt;-110 dBm (measurement bandwidth 10 Hz)\u003c\/li\u003e\n\u003cli\u003e\u0026lt;0.5 ms\/point\u003c\/li\u003e\n\u003cli\u003eFast data transfer via GPIB\u003c\/li\u003e\n\u003cli\u003eTransfer time \u0026lt;15 ms (200 points)\u003c\/li\u003e\n\u003cli\u003eAccurate calibration in test fixtures and on wafers\u003c\/li\u003e\n\u003cli\u003eModern calibration techniques TOM,TRM,TRL,TNA,TOM-X\u003c\/li\u003e\n\u003cli\u003eSwept frequency-conversion and multi tone measurements on amplifiers and mixers\u003c\/li\u003e\n\u003cli\u003eArbitrary configuration of generator and receiver\u003c\/li\u003e\n\u003cli\u003eSelective receiver with fundamental mixing\u003c\/li\u003e\n\u003cli\u003eEasy integration into PC environment and networks\u003c\/li\u003e\n\u003cli\u003eImport of virtual networks using CAE-compatible file formats (*.S1P, *.S2P, *.S4P, *.flp)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Rohde_Schwarz_ZVM_Vector_Network_Analyser_Datasheet.pdf?1726\" title=\"Rohde \u0026amp; Schwarz ZVM Vector Network Analyser Datasheet\"\u003eRohde \u0026amp; Schwarz ZVM Vector Network Analyser Datasheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-05-10T14:45:44+01:00","created_at":"2019-05-10T14:53:01+01:00","vendor":"Rohde \u0026 Schwarz","type":"Network Analyser","tags":["Manufacturer_Rohde \u0026 Schwarz","Network Analysers","Product Type_Network Analyser","Rohde \u0026 Schwarz"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":28171915886670,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ZVM","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Rohde \u0026 Schwarz ZVM Vector Network Analyser","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVM.jpg?v=1562332375"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVM.jpg?v=1562332375","options":["Title"],"media":[{"alt":"Rohde \u0026 Schwarz ZVM Vector Network Analyser, 10 Hz - 20 GHz | MCS Rentals","id":1153715568718,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVM.jpg?v=1562332375"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVM.jpg?v=1562332375","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVM Vector Network Analyser Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Rohde \u0026amp; Schwarz ZVM extend the frequency range of the Rohde \u0026amp; network analysers to 20 GHz. The outstanding performance in terms of speed, dynamic range and accuracy makes it ideal for applications such as S-parameter or group delay measurements. This is enhanced by a wealth of measurement, display and logging functions. In addition, ZVM can be used for complex measurement tasks, such as measurements on frequency-converting DUTs (conversion loss, inter modulation, spurious) and nonlinear measurements (intercept point and compression point).\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVM Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExcellent dynamic range\u003c\/li\u003e\n\u003cli\u003e\u0026gt;115 dB (measurement bandwidth 10 Hz)\u003c\/li\u003e\n\u003cli\u003eLow inherent noise\u003c\/li\u003e\n\u003cli\u003e\u0026lt;-110 dBm (measurement bandwidth 10 Hz)\u003c\/li\u003e\n\u003cli\u003e\u0026lt;0.5 ms\/point\u003c\/li\u003e\n\u003cli\u003eFast data transfer via GPIB\u003c\/li\u003e\n\u003cli\u003eTransfer time \u0026lt;15 ms (200 points)\u003c\/li\u003e\n\u003cli\u003eAccurate calibration in test fixtures and on wafers\u003c\/li\u003e\n\u003cli\u003eModern calibration techniques TOM,TRM,TRL,TNA,TOM-X\u003c\/li\u003e\n\u003cli\u003eSwept frequency-conversion and multi tone measurements on amplifiers and mixers\u003c\/li\u003e\n\u003cli\u003eArbitrary configuration of generator and receiver\u003c\/li\u003e\n\u003cli\u003eSelective receiver with fundamental mixing\u003c\/li\u003e\n\u003cli\u003eEasy integration into PC environment and networks\u003c\/li\u003e\n\u003cli\u003eImport of virtual networks using CAE-compatible file formats (*.S1P, *.S2P, *.S4P, *.flp)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Rohde_Schwarz_ZVM_Vector_Network_Analyser_Datasheet.pdf?1726\" title=\"Rohde \u0026amp; Schwarz ZVM Vector Network Analyser Datasheet\"\u003eRohde \u0026amp; Schwarz ZVM Vector Network Analyser Datasheet\u003c\/a\u003e\u003c\/p\u003e"}
    Rohde & Schwarz ZVM Vector Network Analyser
    Rohde & Schwarz ZVM Vector Network Analyser

    Up to 20 GHz Model Available


    The Rohde & Schwarz ZVM extend the frequency range of the Rohde & network analysers to 20 GHz.
    {"id":3549939957838,"title":"Rohde \u0026 Schwarz ZNB20 Vector Network Analyser","handle":"rohde-schwarz-znb20-vector-network-analyser","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZNB20 Vector Network Analyser Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Rohde \u0026amp; Schwarz ZNB20 vector network analyser features a wide dynamic range of up to 140 dB (at 10 Hz IF bandwidth), low trace noise of less than 0.004 dB RMS (at 10 kHz IF bandwidth) and high output power of up to +13 dBm, which can be adjusted electronically in a range of more than 95 dB. \u003cbr\u003e\u003cbr\u003eThe R\u0026amp;S ZNB20 analyser combines high measurement accuracy with exceptional speed – better than 5 µs per point. It features excellent temperature and long-term stability, which ensures reliable measurements over several days without having to recalibrate the unit. \u003cbr\u003e\u003cbr\u003eThe short-depth, compact four-port analyser leave plenty of space on the workbench for the measurement application. It features low operating noise thanks to low power consumption and a sophisticated cooling concept. The low power consumption also reduces operating costs and protects the environment.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZNB20 Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cli\u003eFrequency range from 9 kHz up to 20 GHz\u003c\/li\u003e\n\u003cli\u003eWide dynamic range of up to 140 dB\u003c\/li\u003e\n\u003cli\u003eShort sweep times, e.g. 4 ms for 401 points\u003c\/li\u003e\n\u003cli\u003eHigh temperature stability of typ. 0.01 dB\/°C\u003c\/li\u003e\n\u003cli\u003eWide power sweep range of 98 dB\u003c\/li\u003e\n\u003cli\u003eWide range of IF bandwidths from 1 Hz to 10 MHz\u003c\/li\u003e\n\u003cli\u003eManual and automatic calibration\u003c\/li\u003e\n\u003cli\u003eLarge, high-resolution 12.1\" screen\u003c\/li\u003e\n\u003cli\u003eTouchscreen user interface\u003c\/li\u003e\n\u003cli\u003eFour-port model with two independent generators\u003c\/li\u003e\n\u003cli\u003eExpansion to up to 48 ports using switch matrices\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eZNB20 Configurations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cstyle\u003e\u003c!--\ntable {\n border-collapse: collapse;\n width: 100%;\n}\n\nth, td {\n text-align: left;\n padding: 8px;\n}\n\ntr:nth-child(even){background-color: #f2f2f2}\n\nth {\n background-color: #a32564;\n color: white;\n}\n--\u003e\u003c\/style\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eRohde \u0026amp; Schwarz ZNB20\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003eModel only\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eConfig 1\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003ca href=\"#pre-order-popup\" class=\"btn-pre-order btn btn-1\"\u003eRequest Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eRohde \u0026amp; Schwarz ZNB20\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003eB2 - Internal second source Generator\u003cbr\u003eB4 - Precision freq. reference\u003cbr\u003eB10 - GPIB interface\u003cbr\u003eB24 - Extended power range ports 1 - 4\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eConfig 2\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003ca href=\"#pre-order-popup\" class=\"btn-pre-order btn btn-1\"\u003eRequest Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eBrochures \u0026amp; Datasheets\u003cbr\u003e\u003c\/strong\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZNB_Vector_Network_Analyser_-_Product_Brochure.pdf?1397\" title=\"R\u0026amp;S ZNB Vector Network Analyser - Product Brochure\"\u003eR\u0026amp;S ZNB Vector Network Analyser - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Precise_measurements_on_high-speed_digital_signal_lines_with_the_R_S_ZNB_-_Application_Card.pdf?1397\" title=\"Precise measurements on high-speed digital signal lines with the R\u0026amp;S ZNB - Application Card\"\u003ePrecise measurements on high-speed digital signal lines with the R\u0026amp;S ZNB - Application Card\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Ground_station_testing_on_satellites_in_orbit.pdf?1397\" title=\"Ground station testing on satellites in orbit\"\u003eGround station testing on satellites in orbit\u003c\/a\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Ground_station_testing_on_satellites_in_orbit.pdf?1397\" title=\"Ground station testing on satellites in orbit\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZNB_Vector_Network_Analyser_-_Specifications.pdf?1397\" title=\"R\u0026amp;S ZNB Vector Network Analyser - Specifications\"\u003eR\u0026amp;S ZNB Vector Network Analyser - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z170_Calibration_Kit_-_Specifications.pdf?1397\" title=\"R\u0026amp;S ZV-Z170 Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-Z170 Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZN-Z85_Switch_Matrix_-_Specifications.pdf?1397\" title=\"R\u0026amp;S ZN-Z85 Switch Matrix - Specifications\"\u003eR\u0026amp;S ZN-Z85 Switch Matrix - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZN-Z25_RFFE_Cable_with_Adaptors_-_Specifications.pdf?1397\" title=\"R\u0026amp;S ZN-Z25 RFFE Cable with Adaptors - Specifications\"\u003eR\u0026amp;S ZN-Z25 RFFE Cable with Adaptors - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZN-Z15_RFFE_Interface_-_Specifications.pdf?1397\" title=\"R\u0026amp;S ZN-Z15 RFFE Interface - Specifications\"\u003eR\u0026amp;S ZN-Z15 RFFE Interface - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZN-Z84_Switch_Matrix_-_Specifications.pdf?1397\" title=\"R\u0026amp;S ZN-Z84 Switch Matrix - Specifications\"\u003eR\u0026amp;S ZN-Z84 Switch Matrix - Specifications\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-05-09T14:10:56+01:00","created_at":"2019-05-09T14:39:53+01:00","vendor":"Rohde \u0026 Schwarz","type":"Network Analyser","tags":["Manufacturer_Rohde \u0026 Schwarz","Network Analysers","Product Type_Network Analyser","Rohde \u0026 Schwarz"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":28161434419278,"title":"Config 1","option1":"Config 1","option2":null,"option3":null,"sku":"ZNB20","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Rohde \u0026 Schwarz ZNB20 Vector Network Analyser - Config 1","public_title":"Config 1","options":["Config 1"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}},{"id":28623619555406,"title":"Config 2","option1":"Config 2","option2":null,"option3":null,"sku":"ZNB20\/B2\/B4\/B10\/B24","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Rohde \u0026 Schwarz ZNB20 Vector Network Analyser - Config 2","public_title":"Config 2","options":["Config 2"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZNB20.jpg?v=1562332372","\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZNB20_Rear.jpg?v=1562332372"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZNB20.jpg?v=1562332372","options":["Configurations"],"media":[{"alt":"Rohde \u0026 Schwarz ZNB20 Vector Network Analyser, 9 kHz - 20 GHz | MCS Rentals","id":1151284117582,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZNB20.jpg?v=1562332372"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZNB20.jpg?v=1562332372","width":600},{"alt":"Rohde \u0026 Schwarz ZNB20 Vector Network Analyser, 9 kHz - 20 GHz | MCS Rentals","id":1195202379854,"position":2,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZNB20_Rear.jpg?v=1562332372"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZNB20_Rear.jpg?v=1562332372","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZNB20 Vector Network Analyser Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Rohde \u0026amp; Schwarz ZNB20 vector network analyser features a wide dynamic range of up to 140 dB (at 10 Hz IF bandwidth), low trace noise of less than 0.004 dB RMS (at 10 kHz IF bandwidth) and high output power of up to +13 dBm, which can be adjusted electronically in a range of more than 95 dB. \u003cbr\u003e\u003cbr\u003eThe R\u0026amp;S ZNB20 analyser combines high measurement accuracy with exceptional speed – better than 5 µs per point. It features excellent temperature and long-term stability, which ensures reliable measurements over several days without having to recalibrate the unit. \u003cbr\u003e\u003cbr\u003eThe short-depth, compact four-port analyser leave plenty of space on the workbench for the measurement application. It features low operating noise thanks to low power consumption and a sophisticated cooling concept. The low power consumption also reduces operating costs and protects the environment.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZNB20 Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cli\u003eFrequency range from 9 kHz up to 20 GHz\u003c\/li\u003e\n\u003cli\u003eWide dynamic range of up to 140 dB\u003c\/li\u003e\n\u003cli\u003eShort sweep times, e.g. 4 ms for 401 points\u003c\/li\u003e\n\u003cli\u003eHigh temperature stability of typ. 0.01 dB\/°C\u003c\/li\u003e\n\u003cli\u003eWide power sweep range of 98 dB\u003c\/li\u003e\n\u003cli\u003eWide range of IF bandwidths from 1 Hz to 10 MHz\u003c\/li\u003e\n\u003cli\u003eManual and automatic calibration\u003c\/li\u003e\n\u003cli\u003eLarge, high-resolution 12.1\" screen\u003c\/li\u003e\n\u003cli\u003eTouchscreen user interface\u003c\/li\u003e\n\u003cli\u003eFour-port model with two independent generators\u003c\/li\u003e\n\u003cli\u003eExpansion to up to 48 ports using switch matrices\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eZNB20 Configurations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cstyle\u003e\u003c!--\ntable {\n border-collapse: collapse;\n width: 100%;\n}\n\nth, td {\n text-align: left;\n padding: 8px;\n}\n\ntr:nth-child(even){background-color: #f2f2f2}\n\nth {\n background-color: #a32564;\n color: white;\n}\n--\u003e\u003c\/style\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eRohde \u0026amp; Schwarz ZNB20\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003eModel only\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eConfig 1\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003ca href=\"#pre-order-popup\" class=\"btn-pre-order btn btn-1\"\u003eRequest Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eRohde \u0026amp; Schwarz ZNB20\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003eB2 - Internal second source Generator\u003cbr\u003eB4 - Precision freq. reference\u003cbr\u003eB10 - GPIB interface\u003cbr\u003eB24 - Extended power range ports 1 - 4\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eConfig 2\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003ca href=\"#pre-order-popup\" class=\"btn-pre-order btn btn-1\"\u003eRequest Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eBrochures \u0026amp; Datasheets\u003cbr\u003e\u003c\/strong\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZNB_Vector_Network_Analyser_-_Product_Brochure.pdf?1397\" title=\"R\u0026amp;S ZNB Vector Network Analyser - Product Brochure\"\u003eR\u0026amp;S ZNB Vector Network Analyser - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Precise_measurements_on_high-speed_digital_signal_lines_with_the_R_S_ZNB_-_Application_Card.pdf?1397\" title=\"Precise measurements on high-speed digital signal lines with the R\u0026amp;S ZNB - Application Card\"\u003ePrecise measurements on high-speed digital signal lines with the R\u0026amp;S ZNB - Application Card\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Ground_station_testing_on_satellites_in_orbit.pdf?1397\" title=\"Ground station testing on satellites in orbit\"\u003eGround station testing on satellites in orbit\u003c\/a\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Ground_station_testing_on_satellites_in_orbit.pdf?1397\" title=\"Ground station testing on satellites in orbit\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZNB_Vector_Network_Analyser_-_Specifications.pdf?1397\" title=\"R\u0026amp;S ZNB Vector Network Analyser - Specifications\"\u003eR\u0026amp;S ZNB Vector Network Analyser - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z170_Calibration_Kit_-_Specifications.pdf?1397\" title=\"R\u0026amp;S ZV-Z170 Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-Z170 Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZN-Z85_Switch_Matrix_-_Specifications.pdf?1397\" title=\"R\u0026amp;S ZN-Z85 Switch Matrix - Specifications\"\u003eR\u0026amp;S ZN-Z85 Switch Matrix - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZN-Z25_RFFE_Cable_with_Adaptors_-_Specifications.pdf?1397\" title=\"R\u0026amp;S ZN-Z25 RFFE Cable with Adaptors - Specifications\"\u003eR\u0026amp;S ZN-Z25 RFFE Cable with Adaptors - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZN-Z15_RFFE_Interface_-_Specifications.pdf?1397\" title=\"R\u0026amp;S ZN-Z15 RFFE Interface - Specifications\"\u003eR\u0026amp;S ZN-Z15 RFFE Interface - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZN-Z84_Switch_Matrix_-_Specifications.pdf?1397\" title=\"R\u0026amp;S ZN-Z84 Switch Matrix - Specifications\"\u003eR\u0026amp;S ZN-Z84 Switch Matrix - Specifications\u003c\/a\u003e\u003c\/p\u003e"}
    Rohde & Schwarz ZNB20 Vector Network Analyser Rohde & Schwarz ZNB20 Vector Network Analyser
    Rohde & Schwarz ZNB20 Vector Network Analyser

    Up to 20 GHz Model Available


    The Rohde & Schwarz ZNB20 vector network analyser features a wide dynamic range of up to 140 dB (at 10 Hz IF bandwidth), low trace noise of less than 0.004 dB RMS (at 10 kHz IF bandwidth) and high output power of up to +13 dBm.
    {"id":3550056611918,"title":"Rohde \u0026 Schwarz ZVA24 Vector Network Analyser","handle":"rohde-schwarz-zva24-vector-network-analyser","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVA24 Vector Network Analyser Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Rohde \u0026amp; Schwarz ZVA24 is an ideal choice for demanding measurements in the lab and in production – from filter measurements requiring maximum dynamic range to linear and nonlinear measurements on amplifiers and mixers as well as on receivers and transceivers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eThe R\u0026amp;S ZVA Network Analyser series has set milestones for the most challenging applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFirst VNA with four internal sources up to 67 GHz for fast two-tone measurements on amplifiers and mixers\u003c\/li\u003e\n\u003cli\u003eFirst VNA up to 67 GHz that generates phase-coherent signals\u003c\/li\u003e\n\u003cli\u003eFirst VNA with IF bandwidths up to 30 MHz for pulsed measurements on amplifiers and mixers up to 110 GHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVA24 Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cli\u003eLinear and nonlinear amplifier and mixer measurements\u003c\/li\u003e\n\u003cli\u003eNoise figure measurements\u003c\/li\u003e\n\u003cli\u003ePulse profile measurements with 12.5 ns resolution\u003c\/li\u003e\n\u003cli\u003eTrue differential measurements for reliable characterisation of active devices with balanced ports\u003c\/li\u003e\n\u003cli\u003eHigh output power typ. \u0026gt; 18 dBm\u003c\/li\u003e\n\u003cli\u003eWide dynamic range typ. \u0026gt; 140 dB\u003c\/li\u003e\n\u003cli\u003eHigh measurement speed \u0026lt; 3.5 μs per test point\u003c\/li\u003e\n\u003cli\u003eWide IF bandwidth: 1\/5\/30 MHz\u003c\/li\u003e\n\u003cli\u003eVersatile calibration techniques: TOSM, TRL\/LRL, TOM, TRM, TNA, UOSM\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration units\u003c\/li\u003e\n\u003cli\u003ePhase and group delay measurements on mixers with and without LO access\u003c\/li\u003e\n\u003cli\u003eFrequency range: 300 kHz to 8 GHz (R\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA8), 10 MHz to 24\/40\/50\/67\/110 GHz (R\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA24\/40\/50\/67\/110)\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eZVA24 Configurations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cstyle\u003e\u003c!--\ntable {\n border-collapse: collapse;\n width: 100%;\n}\n\nth, td {\n text-align: left;\n padding: 8px;\n}\n\ntr:nth-child(even){background-color: #f2f2f2}\n\nth {\n background-color: #a32564;\n color: white;\n}\n--\u003e\u003c\/style\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eRohde \u0026amp; Schwarz ZVA24\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003eModel only\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eConfig 1\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003ca href=\"#pre-order-popup\" class=\"btn-pre-order btn btn-1\"\u003eRequest Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eRohde \u0026amp; Schwarz ZVA24\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003e4-Port\u003cbr\u003eB16 - Direct generator\/receiver for 2 port ZVA24\u003cbr\u003eB21 - Generator step attenuator, port 1\u003cbr\u003eB22 - Generator step attenuator, port 2\u003cbr\u003eB31 - Receiver step attenuator, port 1\u003cbr\u003eB32 - Receiver step attenuator port 2\u003cbr\u003eB33 - Receiver step attenuator port 3\u003cbr\u003eB34 - Receiver step attenuator port 4\u003cbr\u003eK2 - Time domain (TDR)\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eConfig 2\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003ca href=\"#pre-order-popup\" class=\"btn-pre-order btn btn-1\"\u003eRequest Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003cdiv id=\"ti_expandedbox_c_t-9660.9\" class=\"tbl col3\"\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA40\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test ports\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 or 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e300 kHz to 8 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 24 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 40 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test points per trace\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 to 60001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eMeasurement bandwidths\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 Hz to 1 MHz (with option: up to 30 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. number of internal sources\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eOperating system\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWindows XP Embedded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDynamic range at 10 Hz measurement bandwidth:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetween test ports\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 135 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eWith direct receiver access\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 145 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 145 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 150 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003ePower range (typ)\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–45 dBm to +15 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +18 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +18 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith optional step attenuators\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eGenerator step attenuators extend the lower limit of the output power range by 70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement time per test point\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 3.5 μs (at 1 MHz measurement bandwidth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003eData transfer time (for 201 measurements points):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evia IEC\/IEEE bus\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 2.9 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003evia VX11 over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evia RSIB over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 0.7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eSwitching time between channels\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching time between instrument setups\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 10 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"ti_expandedbox_c_t-9660.10\" class=\"tbl col3\"\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA67\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA110\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test ports\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 or 4\u003c\/td\u003e\n\u003ctd\u003e2 (base unit\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eR\u0026amp;S\u003csup\u003e®\u003c\/sup\u003eZVA67:\u003cbr\u003e4 ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 50 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 kHz to 67 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 110 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test points per trace\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 to 60001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eMeasurement bandwidths\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 Hz to 1 MHz (with option: up to 30 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. number of internal sources\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4 (base unit\u003cbr\u003eR\u0026amp;S\u003csup\u003e®\u003c\/sup\u003eZVA67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eOperating system\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWindows XP Embedded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDynamic range at 10 Hz measurement bandwidth:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetween test ports\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 130 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eWith direct receiver access\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 150 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 145 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eOutput power at test port\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 18 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 18 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 8 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower range (typ)\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +15 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +18 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–30 dBm to +8 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eWith optional step attenuators\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGenerator step attenuators extend the lower\u003cbr\u003elimit of the output power range by 50 dB\u003c\/td\u003e\n\u003ctd\u003e(no step attneuators)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eMeasurement time per test point\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 3.5 μs (at 1 MHz measurement bandwidth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eData transfer time (for 201 measurements points):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003evia IEC\/IEEE bus\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 2.9 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evia VX11 over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003evia RSIB over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 0.7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching time between channels\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eSwitching time between instrument setups\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 10 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA_Vector_Network_Analyser_-_Specifications.pdf?1411\" title=\"R\u0026amp;S ZVA Vector Network Analyser - Specifications\"\u003eR\u0026amp;S ZVA Vector Network Analyser - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA110_Network_Analyser_-_Specifications.pdf?1410\" title=\"R\u0026amp;S ZVA110 Network Analyser - Specifications\"\u003eR\u0026amp;S ZVA110 Network Analyser - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA-Zxx_Millimeter-Wave_Converters_-_Specifications.pdf?1411\" title=\"R\u0026amp;S ZVA-Zxx Millimeter-Wave Converters - Specifications\"\u003eR\u0026amp;S ZVA-Zxx Millimeter-Wave Converters - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z3xx_T-Checker_-_Specifications.pdf?1411\" title=\"R\u0026amp;S ZV-Z3xx T-Checker - Specifications\"\u003eR\u0026amp;S ZV-Z3xx T-Checker - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVAX-TRM_Extension_Unit_-_Specifications.pdf?1413\" title=\"R\u0026amp;S ZVAX-TRM Extension Unit - Specifications\"\u003eR\u0026amp;S ZVAX-TRM Extension Unit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z129_Calibration_Kits_-_Specifications.pdf?1415\" title=\"R\u0026amp;S ZV-Z129 Calibration Kits - Specifications\"\u003eR\u0026amp;S ZV-Z129 Calibration Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-WRxx_R_S_ZCWM-570_Waveguide_Calibration_Kits_-_Specifications.pdf?1418\" title=\"R\u0026amp;S ZV-WRxx R\u0026amp;S ZCWM-570 Waveguide Calibration Kits - Specifications\"\u003eR\u0026amp;S ZV-WRxx R\u0026amp;S ZCWM-570 Waveguide Calibration Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z4xx_Mechanical_Verification_Kits_-_Specifications.pdf?1417\" title=\"R\u0026amp;S ZV-Z4xx Mechanical Verification Kits - Specifications\"\u003eR\u0026amp;S ZV-Z4xx Mechanical Verification Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVAX24_Extension_Unit_-_Specifications.pdf?1419\" title=\"R\u0026amp;S ZVAX24 Extension Unit - Specifications\"\u003eR\u0026amp;S ZVAX24 Extension Unit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z170_Calibration_Kit_-_Specifications.pdf?1420\" title=\"R\u0026amp;S ZV-Z170 Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-Z170 Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-ZCAN_Calibration_Kit_-_Specifications.pdf?1422\" title=\"R\u0026amp;S ZV-ZCAN Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-ZCAN Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZCxxx_Millimeter-Wave_Converters_-_Specifications.pdf?1422\" title=\"R\u0026amp;S ZCxxx Millimeter-Wave Converters - Specifications\"\u003eR\u0026amp;S ZCxxx Millimeter-Wave Converters - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z2xx_Calibration_Kits_-_Specifications.pdf?1423\" title=\"R\u0026amp;S ZV-Z2xx Calibration Kits - Specifications\"\u003eR\u0026amp;S ZV-Z2xx Calibration Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z9x_ZV-Z19x_Test_Port_Cables_-_Specifications.pdf?1425\" title=\"R\u0026amp;S ZV-Z9x, ZV-Z19x Test Port Cables - Specifications\"\u003eR\u0026amp;S ZV-Z9x, ZV-Z19x Test Port Cables - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z5x_Calibration_Unit_-_Specifications.pdf?1426\" title=\"R\u0026amp;S ZV-Z5x Calibration Unit - Specifications\"\u003eR\u0026amp;S ZV-Z5x Calibration Unit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBrochures\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA-Zxx_Millimeter_Wave_Converters_-_Product_Brochure.pdf?1427\" title=\"R\u0026amp;S ZVA-Zxx Millimeter Wave Converters - Product Brochure\"\u003eR\u0026amp;S ZVA-Zxx Millimeter Wave Converters - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA_Vector_Network_Analyzer_-_Product_Brochure.pdf?1428\" title=\"R\u0026amp;S ZVA Vector Network Analyser - Product Brochure\"\u003eR\u0026amp;S ZVA Vector Network Analyser - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Ground_station_testing_on_satellites_in_orbit.pdf?1428\" title=\"Ground station testing on satellites in orbit\"\u003eGround station testing on satellites in orbit\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-ZCAN_Calibration_Kit_-_Product_Brochure.pdf?1430\" title=\"R\u0026amp;S ZV-ZCAN Calibration Kit - Product Brochure\"\u003eR\u0026amp;S ZV-ZCAN Calibration Kit - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVAX_TRM_Extension_Unit_-_Product_Brochure.pdf?1430\" title=\"R\u0026amp;S ZVAX‑TRM Extension Unit - Product Brochure\"\u003eR\u0026amp;S ZVAX‑TRM Extension Unit - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_LegacyPro_Instrument_emulation_Breathing_new_life_into_existing_test_systems_-_Brochure.pdf?1431\" title=\"R\u0026amp;S LegacyPro Instrument emulation – Breathing new life into existing test systems - Brochure\"\u003eR\u0026amp;S LegacyPro Instrument emulation – Breathing new life into existing test systems - Brochure\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-05-09T16:21:00+01:00","created_at":"2019-05-09T16:56:33+01:00","vendor":"Rohde \u0026 Schwarz","type":"Network Analyser","tags":["Manufacturer_Rohde \u0026 Schwarz","Network Analysers","Product Type_Network Analyser","Rohde \u0026 Schwarz"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":28162223472718,"title":"Config 1","option1":"Config 1","option2":null,"option3":null,"sku":"ZVA24","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Rohde \u0026 Schwarz ZVA24 Vector Network Analyser - Config 1","public_title":"Config 1","options":["Config 1"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}},{"id":29135623127118,"title":"Config 2","option1":"Config 2","option2":null,"option3":null,"sku":"ZVA24\/4P\/B16\/B21\/B22\/B31\/B32\/B33\/B34\/K2","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Rohde \u0026 Schwarz ZVA24 Vector Network Analyser - Config 2","public_title":"Config 2","options":["Config 2"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVA.jpg?v=1562332373"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVA.jpg?v=1562332373","options":["Configurations"],"media":[{"alt":"Rohde \u0026 Schwarz ZVA24 Vector Network Analyser, 10 MHz - 24 GHz | MCS Rentals","id":1153030258766,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVA.jpg?v=1562332373"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVA.jpg?v=1562332373","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVA24 Vector Network Analyser Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Rohde \u0026amp; Schwarz ZVA24 is an ideal choice for demanding measurements in the lab and in production – from filter measurements requiring maximum dynamic range to linear and nonlinear measurements on amplifiers and mixers as well as on receivers and transceivers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eThe R\u0026amp;S ZVA Network Analyser series has set milestones for the most challenging applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFirst VNA with four internal sources up to 67 GHz for fast two-tone measurements on amplifiers and mixers\u003c\/li\u003e\n\u003cli\u003eFirst VNA up to 67 GHz that generates phase-coherent signals\u003c\/li\u003e\n\u003cli\u003eFirst VNA with IF bandwidths up to 30 MHz for pulsed measurements on amplifiers and mixers up to 110 GHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVA24 Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cli\u003eLinear and nonlinear amplifier and mixer measurements\u003c\/li\u003e\n\u003cli\u003eNoise figure measurements\u003c\/li\u003e\n\u003cli\u003ePulse profile measurements with 12.5 ns resolution\u003c\/li\u003e\n\u003cli\u003eTrue differential measurements for reliable characterisation of active devices with balanced ports\u003c\/li\u003e\n\u003cli\u003eHigh output power typ. \u0026gt; 18 dBm\u003c\/li\u003e\n\u003cli\u003eWide dynamic range typ. \u0026gt; 140 dB\u003c\/li\u003e\n\u003cli\u003eHigh measurement speed \u0026lt; 3.5 μs per test point\u003c\/li\u003e\n\u003cli\u003eWide IF bandwidth: 1\/5\/30 MHz\u003c\/li\u003e\n\u003cli\u003eVersatile calibration techniques: TOSM, TRL\/LRL, TOM, TRM, TNA, UOSM\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration units\u003c\/li\u003e\n\u003cli\u003ePhase and group delay measurements on mixers with and without LO access\u003c\/li\u003e\n\u003cli\u003eFrequency range: 300 kHz to 8 GHz (R\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA8), 10 MHz to 24\/40\/50\/67\/110 GHz (R\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA24\/40\/50\/67\/110)\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eZVA24 Configurations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cstyle\u003e\u003c!--\ntable {\n border-collapse: collapse;\n width: 100%;\n}\n\nth, td {\n text-align: left;\n padding: 8px;\n}\n\ntr:nth-child(even){background-color: #f2f2f2}\n\nth {\n background-color: #a32564;\n color: white;\n}\n--\u003e\u003c\/style\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eRohde \u0026amp; Schwarz ZVA24\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003eModel only\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eConfig 1\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003ca href=\"#pre-order-popup\" class=\"btn-pre-order btn btn-1\"\u003eRequest Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eRohde \u0026amp; Schwarz ZVA24\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003e4-Port\u003cbr\u003eB16 - Direct generator\/receiver for 2 port ZVA24\u003cbr\u003eB21 - Generator step attenuator, port 1\u003cbr\u003eB22 - Generator step attenuator, port 2\u003cbr\u003eB31 - Receiver step attenuator, port 1\u003cbr\u003eB32 - Receiver step attenuator port 2\u003cbr\u003eB33 - Receiver step attenuator port 3\u003cbr\u003eB34 - Receiver step attenuator port 4\u003cbr\u003eK2 - Time domain (TDR)\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eConfig 2\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003ca href=\"#pre-order-popup\" class=\"btn-pre-order btn btn-1\"\u003eRequest Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003cdiv id=\"ti_expandedbox_c_t-9660.9\" class=\"tbl col3\"\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA40\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test ports\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 or 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e300 kHz to 8 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 24 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 40 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test points per trace\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 to 60001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eMeasurement bandwidths\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 Hz to 1 MHz (with option: up to 30 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. number of internal sources\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eOperating system\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWindows XP Embedded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDynamic range at 10 Hz measurement bandwidth:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetween test ports\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 135 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eWith direct receiver access\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 145 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 145 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 150 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003ePower range (typ)\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–45 dBm to +15 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +18 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +18 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith optional step attenuators\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eGenerator step attenuators extend the lower limit of the output power range by 70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement time per test point\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 3.5 μs (at 1 MHz measurement bandwidth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003eData transfer time (for 201 measurements points):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evia IEC\/IEEE bus\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 2.9 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003evia VX11 over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evia RSIB over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 0.7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eSwitching time between channels\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching time between instrument setups\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 10 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"ti_expandedbox_c_t-9660.10\" class=\"tbl col3\"\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA67\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA110\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test ports\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 or 4\u003c\/td\u003e\n\u003ctd\u003e2 (base unit\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eR\u0026amp;S\u003csup\u003e®\u003c\/sup\u003eZVA67:\u003cbr\u003e4 ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 50 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 kHz to 67 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 110 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test points per trace\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 to 60001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eMeasurement bandwidths\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 Hz to 1 MHz (with option: up to 30 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. number of internal sources\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4 (base unit\u003cbr\u003eR\u0026amp;S\u003csup\u003e®\u003c\/sup\u003eZVA67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eOperating system\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWindows XP Embedded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDynamic range at 10 Hz measurement bandwidth:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetween test ports\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 130 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eWith direct receiver access\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 150 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 145 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eOutput power at test port\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 18 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 18 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 8 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower range (typ)\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +15 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +18 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–30 dBm to +8 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eWith optional step attenuators\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGenerator step attenuators extend the lower\u003cbr\u003elimit of the output power range by 50 dB\u003c\/td\u003e\n\u003ctd\u003e(no step attneuators)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eMeasurement time per test point\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 3.5 μs (at 1 MHz measurement bandwidth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eData transfer time (for 201 measurements points):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003evia IEC\/IEEE bus\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 2.9 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evia VX11 over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003evia RSIB over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 0.7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching time between channels\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eSwitching time between instrument setups\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 10 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA_Vector_Network_Analyser_-_Specifications.pdf?1411\" title=\"R\u0026amp;S ZVA Vector Network Analyser - Specifications\"\u003eR\u0026amp;S ZVA Vector Network Analyser - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA110_Network_Analyser_-_Specifications.pdf?1410\" title=\"R\u0026amp;S ZVA110 Network Analyser - Specifications\"\u003eR\u0026amp;S ZVA110 Network Analyser - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA-Zxx_Millimeter-Wave_Converters_-_Specifications.pdf?1411\" title=\"R\u0026amp;S ZVA-Zxx Millimeter-Wave Converters - Specifications\"\u003eR\u0026amp;S ZVA-Zxx Millimeter-Wave Converters - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z3xx_T-Checker_-_Specifications.pdf?1411\" title=\"R\u0026amp;S ZV-Z3xx T-Checker - Specifications\"\u003eR\u0026amp;S ZV-Z3xx T-Checker - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVAX-TRM_Extension_Unit_-_Specifications.pdf?1413\" title=\"R\u0026amp;S ZVAX-TRM Extension Unit - Specifications\"\u003eR\u0026amp;S ZVAX-TRM Extension Unit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z129_Calibration_Kits_-_Specifications.pdf?1415\" title=\"R\u0026amp;S ZV-Z129 Calibration Kits - Specifications\"\u003eR\u0026amp;S ZV-Z129 Calibration Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-WRxx_R_S_ZCWM-570_Waveguide_Calibration_Kits_-_Specifications.pdf?1418\" title=\"R\u0026amp;S ZV-WRxx R\u0026amp;S ZCWM-570 Waveguide Calibration Kits - Specifications\"\u003eR\u0026amp;S ZV-WRxx R\u0026amp;S ZCWM-570 Waveguide Calibration Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z4xx_Mechanical_Verification_Kits_-_Specifications.pdf?1417\" title=\"R\u0026amp;S ZV-Z4xx Mechanical Verification Kits - Specifications\"\u003eR\u0026amp;S ZV-Z4xx Mechanical Verification Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVAX24_Extension_Unit_-_Specifications.pdf?1419\" title=\"R\u0026amp;S ZVAX24 Extension Unit - Specifications\"\u003eR\u0026amp;S ZVAX24 Extension Unit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z170_Calibration_Kit_-_Specifications.pdf?1420\" title=\"R\u0026amp;S ZV-Z170 Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-Z170 Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-ZCAN_Calibration_Kit_-_Specifications.pdf?1422\" title=\"R\u0026amp;S ZV-ZCAN Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-ZCAN Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZCxxx_Millimeter-Wave_Converters_-_Specifications.pdf?1422\" title=\"R\u0026amp;S ZCxxx Millimeter-Wave Converters - Specifications\"\u003eR\u0026amp;S ZCxxx Millimeter-Wave Converters - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z2xx_Calibration_Kits_-_Specifications.pdf?1423\" title=\"R\u0026amp;S ZV-Z2xx Calibration Kits - Specifications\"\u003eR\u0026amp;S ZV-Z2xx Calibration Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z9x_ZV-Z19x_Test_Port_Cables_-_Specifications.pdf?1425\" title=\"R\u0026amp;S ZV-Z9x, ZV-Z19x Test Port Cables - Specifications\"\u003eR\u0026amp;S ZV-Z9x, ZV-Z19x Test Port Cables - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z5x_Calibration_Unit_-_Specifications.pdf?1426\" title=\"R\u0026amp;S ZV-Z5x Calibration Unit - Specifications\"\u003eR\u0026amp;S ZV-Z5x Calibration Unit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBrochures\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA-Zxx_Millimeter_Wave_Converters_-_Product_Brochure.pdf?1427\" title=\"R\u0026amp;S ZVA-Zxx Millimeter Wave Converters - Product Brochure\"\u003eR\u0026amp;S ZVA-Zxx Millimeter Wave Converters - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA_Vector_Network_Analyzer_-_Product_Brochure.pdf?1428\" title=\"R\u0026amp;S ZVA Vector Network Analyser - Product Brochure\"\u003eR\u0026amp;S ZVA Vector Network Analyser - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Ground_station_testing_on_satellites_in_orbit.pdf?1428\" title=\"Ground station testing on satellites in orbit\"\u003eGround station testing on satellites in orbit\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-ZCAN_Calibration_Kit_-_Product_Brochure.pdf?1430\" title=\"R\u0026amp;S ZV-ZCAN Calibration Kit - Product Brochure\"\u003eR\u0026amp;S ZV-ZCAN Calibration Kit - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVAX_TRM_Extension_Unit_-_Product_Brochure.pdf?1430\" title=\"R\u0026amp;S ZVAX‑TRM Extension Unit - Product Brochure\"\u003eR\u0026amp;S ZVAX‑TRM Extension Unit - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_LegacyPro_Instrument_emulation_Breathing_new_life_into_existing_test_systems_-_Brochure.pdf?1431\" title=\"R\u0026amp;S LegacyPro Instrument emulation – Breathing new life into existing test systems - Brochure\"\u003eR\u0026amp;S LegacyPro Instrument emulation – Breathing new life into existing test systems - Brochure\u003c\/a\u003e\u003c\/p\u003e"}
    Rohde & Schwarz ZVA24 Vector Network Analyser
    Rohde & Schwarz ZVA24 Vector Network Analyser

    Up to 24 GHz Model Available


    The Rohde & Schwarz ZVA24 is an ideal choice for demanding measurements in the lab and in production – from filter measurements requiring maximum dynamic range to linear and nonlinear measurements on amplifiers and mixers as well as on receivers and transceivers.
    {"id":3550729764942,"title":"Rohde \u0026 Schwarz ZVA40 Vector Network Analyser","handle":"rohde-schwarz-zva40-vector-network-analyser","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVA40 Vector Network Analyser Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Rohde \u0026amp; Schwarz ZVA40 is an ideal choice for demanding measurements in the lab and in production – from filter measurements requiring maximum dynamic range to linear and nonlinear measurements on amplifiers and mixers as well as on receivers and transceivers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eThe R\u0026amp;S ZVA Network Analyser series has set milestones for the most challenging applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFirst VNA with four internal sources up to 67 GHz for fast two-tone measurements on amplifiers and mixers\u003c\/li\u003e\n\u003cli\u003eFirst VNA up to 67 GHz that generates phase-coherent signals\u003c\/li\u003e\n\u003cli\u003eFirst VNA with IF bandwidths up to 30 MHz for pulsed measurements on amplifiers and mixers up to 110 GHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVA40 Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cli\u003eLinear and nonlinear amplifier and mixer measurements\u003c\/li\u003e\n\u003cli\u003eNoise figure measurements\u003c\/li\u003e\n\u003cli\u003ePulse profile measurements with 12.5 ns resolution\u003c\/li\u003e\n\u003cli\u003eTrue differential measurements for reliable characterisation of active devices with balanced ports\u003c\/li\u003e\n\u003cli\u003eHigh output power typ. \u0026gt; 18 dBm\u003c\/li\u003e\n\u003cli\u003eWide dynamic range typ. \u0026gt; 140 dB\u003c\/li\u003e\n\u003cli\u003eHigh measurement speed \u0026lt; 3.5 μs per test point\u003c\/li\u003e\n\u003cli\u003eWide IF bandwidth: 1\/5\/30 MHz\u003c\/li\u003e\n\u003cli\u003eVersatile calibration techniques: TOSM, TRL\/LRL, TOM, TRM, TNA, UOSM\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration units\u003c\/li\u003e\n\u003cli\u003ePhase and group delay measurements on mixers with and without LO access\u003c\/li\u003e\n\u003cli\u003eFrequency range: 300 kHz to 8 GHz (R\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA8), 10 MHz to 24\/40\/50\/67\/110 GHz (R\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA24\/40\/50\/67\/110)\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eZVA40 Configurations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cstyle\u003e\u003c!--\ntable {\n border-collapse: collapse;\n width: 100%;\n}\n\nth, td {\n text-align: left;\n padding: 8px;\n}\n\ntr:nth-child(even){background-color: #f2f2f2}\n\nth {\n background-color: #a32564;\n color: white;\n}\n--\u003e\u003c\/style\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eRohde \u0026amp; Schwarz ZVA40\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003eModel only\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eConfig 1\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003ca href=\"#pre-order-popup\" class=\"btn-pre-order btn btn-1\"\u003eRequest Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eRohde \u0026amp; Schwarz ZVA40\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003e\n\u003cspan\u003e4-Port\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB4 - Oven quartz (OCXO)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB16 - Direct generator\/receiver access for 4 port ZVA40\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB18 - Removable flash disk 4 GB\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB21 - Generator step attenuator, port 1\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB23 - Generator step attenuator, port 3\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB32 - Receiver step attenuator, port 2\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB34 - Receiver step attenuator, port 4\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eK4 - Frequency Conversion\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eK9 - Embedded LO mixer delay measurements\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eConfig 2\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003ca href=\"#pre-order-popup\" class=\"btn-pre-order btn btn-1\"\u003eRequest Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003cdiv id=\"ti_expandedbox_c_t-9660.9\" class=\"tbl col3\"\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA40\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test ports\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 or 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e300 kHz to 8 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 24 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 40 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test points per trace\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 to 60001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eMeasurement bandwidths\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 Hz to 1 MHz (with option: up to 30 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. number of internal sources\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eOperating system\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWindows XP Embedded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDynamic range at 10 Hz measurement bandwidth:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetween test ports\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 135 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eWith direct receiver access\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 145 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 145 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 150 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003ePower range (typ)\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–45 dBm to +15 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +18 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +18 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith optional step attenuators\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eGenerator step attenuators extend the lower limit of the output power range by 70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement time per test point\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 3.5 μs (at 1 MHz measurement bandwidth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003eData transfer time (for 201 measurements points):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evia IEC\/IEEE bus\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 2.9 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003evia VX11 over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evia RSIB over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 0.7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eSwitching time between channels\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching time between instrument setups\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 10 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"ti_expandedbox_c_t-9660.10\" class=\"tbl col3\"\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA67\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA110\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test ports\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 or 4\u003c\/td\u003e\n\u003ctd\u003e2 (base unit\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eR\u0026amp;S\u003csup\u003e®\u003c\/sup\u003eZVA67:\u003cbr\u003e4 ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 50 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 kHz to 67 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 110 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test points per trace\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 to 60001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eMeasurement bandwidths\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 Hz to 1 MHz (with option: up to 30 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. number of internal sources\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4 (base unit\u003cbr\u003eR\u0026amp;S\u003csup\u003e®\u003c\/sup\u003eZVA67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eOperating system\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWindows XP Embedded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDynamic range at 10 Hz measurement bandwidth:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetween test ports\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 130 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eWith direct receiver access\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 150 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 145 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eOutput power at test port\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 18 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 18 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 8 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower range (typ)\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +15 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +18 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–30 dBm to +8 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eWith optional step attenuators\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGenerator step attenuators extend the lower\u003cbr\u003elimit of the output power range by 50 dB\u003c\/td\u003e\n\u003ctd\u003e(no step attneuators)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eMeasurement time per test point\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 3.5 μs (at 1 MHz measurement bandwidth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eData transfer time (for 201 measurements points):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003evia IEC\/IEEE bus\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 2.9 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evia VX11 over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003evia RSIB over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 0.7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching time between channels\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eSwitching time between instrument setups\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 10 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA_Vector_Network_Analyser_-_Specifications.pdf?1411\" title=\"R\u0026amp;S ZVA Vector Network Analyser - Specifications\"\u003eR\u0026amp;S ZVA Vector Network Analyser - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA110_Network_Analyser_-_Specifications.pdf?1410\" title=\"R\u0026amp;S ZVA110 Network Analyser - Specifications\"\u003eR\u0026amp;S ZVA110 Network Analyser - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA-Zxx_Millimeter-Wave_Converters_-_Specifications.pdf?1411\" title=\"R\u0026amp;S ZVA-Zxx Millimeter-Wave Converters - Specifications\"\u003eR\u0026amp;S ZVA-Zxx Millimeter-Wave Converters - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z3xx_T-Checker_-_Specifications.pdf?1411\" title=\"R\u0026amp;S ZV-Z3xx T-Checker - Specifications\"\u003eR\u0026amp;S ZV-Z3xx T-Checker - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVAX-TRM_Extension_Unit_-_Specifications.pdf?1413\" title=\"R\u0026amp;S ZVAX-TRM Extension Unit - Specifications\"\u003eR\u0026amp;S ZVAX-TRM Extension Unit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z129_Calibration_Kits_-_Specifications.pdf?1415\" title=\"R\u0026amp;S ZV-Z129 Calibration Kits - Specifications\"\u003eR\u0026amp;S ZV-Z129 Calibration Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-WRxx_R_S_ZCWM-570_Waveguide_Calibration_Kits_-_Specifications.pdf?1418\" title=\"R\u0026amp;S ZV-WRxx R\u0026amp;S ZCWM-570 Waveguide Calibration Kits - Specifications\"\u003eR\u0026amp;S ZV-WRxx R\u0026amp;S ZCWM-570 Waveguide Calibration Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z4xx_Mechanical_Verification_Kits_-_Specifications.pdf?1417\" title=\"R\u0026amp;S ZV-Z4xx Mechanical Verification Kits - Specifications\"\u003eR\u0026amp;S ZV-Z4xx Mechanical Verification Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVAX24_Extension_Unit_-_Specifications.pdf?1419\" title=\"R\u0026amp;S ZVAX24 Extension Unit - Specifications\"\u003eR\u0026amp;S ZVAX24 Extension Unit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z170_Calibration_Kit_-_Specifications.pdf?1420\" title=\"R\u0026amp;S ZV-Z170 Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-Z170 Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-ZCAN_Calibration_Kit_-_Specifications.pdf?1422\" title=\"R\u0026amp;S ZV-ZCAN Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-ZCAN Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZCxxx_Millimeter-Wave_Converters_-_Specifications.pdf?1422\" title=\"R\u0026amp;S ZCxxx Millimeter-Wave Converters - Specifications\"\u003eR\u0026amp;S ZCxxx Millimeter-Wave Converters - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z2xx_Calibration_Kits_-_Specifications.pdf?1423\" title=\"R\u0026amp;S ZV-Z2xx Calibration Kits - Specifications\"\u003eR\u0026amp;S ZV-Z2xx Calibration Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z9x_ZV-Z19x_Test_Port_Cables_-_Specifications.pdf?1425\" title=\"R\u0026amp;S ZV-Z9x, ZV-Z19x Test Port Cables - Specifications\"\u003eR\u0026amp;S ZV-Z9x, ZV-Z19x Test Port Cables - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z5x_Calibration_Unit_-_Specifications.pdf?1426\" title=\"R\u0026amp;S ZV-Z5x Calibration Unit - Specifications\"\u003eR\u0026amp;S ZV-Z5x Calibration Unit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBrochures\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA-Zxx_Millimeter_Wave_Converters_-_Product_Brochure.pdf?1427\" title=\"R\u0026amp;S ZVA-Zxx Millimeter Wave Converters - Product Brochure\"\u003eR\u0026amp;S ZVA-Zxx Millimeter Wave Converters - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA_Vector_Network_Analyzer_-_Product_Brochure.pdf?1428\" title=\"R\u0026amp;S ZVA Vector Network Analyser - Product Brochure\"\u003eR\u0026amp;S ZVA Vector Network Analyser - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Ground_station_testing_on_satellites_in_orbit.pdf?1428\" title=\"Ground station testing on satellites in orbit\"\u003eGround station testing on satellites in orbit\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-ZCAN_Calibration_Kit_-_Product_Brochure.pdf?1430\" title=\"R\u0026amp;S ZV-ZCAN Calibration Kit - Product Brochure\"\u003eR\u0026amp;S ZV-ZCAN Calibration Kit - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVAX_TRM_Extension_Unit_-_Product_Brochure.pdf?1430\" title=\"R\u0026amp;S ZVAX‑TRM Extension Unit - Product Brochure\"\u003eR\u0026amp;S ZVAX‑TRM Extension Unit - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_LegacyPro_Instrument_emulation_Breathing_new_life_into_existing_test_systems_-_Brochure.pdf?1431\" title=\"R\u0026amp;S LegacyPro Instrument emulation – Breathing new life into existing test systems - Brochure\"\u003eR\u0026amp;S LegacyPro Instrument emulation – Breathing new life into existing test systems - Brochure\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-05-10T09:54:37+01:00","created_at":"2019-05-10T09:54:37+01:00","vendor":"Rohde \u0026 Schwarz","type":"Network Analyser","tags":["Manufacturer_Rohde \u0026 Schwarz","Network Analysers","Product Type_Network Analyser","Rohde \u0026 Schwarz"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":28169189032014,"title":"Config 1","option1":"Config 1","option2":null,"option3":null,"sku":"ZVA40","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Rohde \u0026 Schwarz ZVA40 Vector Network Analyser - Config 1","public_title":"Config 1","options":["Config 1"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}},{"id":29135765504078,"title":"Config 2","option1":"Config 2","option2":null,"option3":null,"sku":"ZVA40\/4P\/B4\/B16\/B18\/B21\/B23\/B32\/B34\/K4\/K9","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"Rohde \u0026 Schwarz ZVA40 Vector Network Analyser - Config 2","public_title":"Config 2","options":["Config 2"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVA_42506459-ac0e-4dd2-b021-7c735885b6c9.jpg?v=1562332374"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVA_42506459-ac0e-4dd2-b021-7c735885b6c9.jpg?v=1562332374","options":["Configurations"],"media":[{"alt":"Rohde \u0026 Schwarz ZVA40 Vector Network Analyser, 10 MHz - 40 GHz | MCS Rentals","id":1153035567182,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVA_42506459-ac0e-4dd2-b021-7c735885b6c9.jpg?v=1562332374"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/products\/ZVA_42506459-ac0e-4dd2-b021-7c735885b6c9.jpg?v=1562332374","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVA40 Vector Network Analyser Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Rohde \u0026amp; Schwarz ZVA40 is an ideal choice for demanding measurements in the lab and in production – from filter measurements requiring maximum dynamic range to linear and nonlinear measurements on amplifiers and mixers as well as on receivers and transceivers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eThe R\u0026amp;S ZVA Network Analyser series has set milestones for the most challenging applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFirst VNA with four internal sources up to 67 GHz for fast two-tone measurements on amplifiers and mixers\u003c\/li\u003e\n\u003cli\u003eFirst VNA up to 67 GHz that generates phase-coherent signals\u003c\/li\u003e\n\u003cli\u003eFirst VNA with IF bandwidths up to 30 MHz for pulsed measurements on amplifiers and mixers up to 110 GHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eRohde \u0026amp; Schwarz ZVA40 Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cli\u003eLinear and nonlinear amplifier and mixer measurements\u003c\/li\u003e\n\u003cli\u003eNoise figure measurements\u003c\/li\u003e\n\u003cli\u003ePulse profile measurements with 12.5 ns resolution\u003c\/li\u003e\n\u003cli\u003eTrue differential measurements for reliable characterisation of active devices with balanced ports\u003c\/li\u003e\n\u003cli\u003eHigh output power typ. \u0026gt; 18 dBm\u003c\/li\u003e\n\u003cli\u003eWide dynamic range typ. \u0026gt; 140 dB\u003c\/li\u003e\n\u003cli\u003eHigh measurement speed \u0026lt; 3.5 μs per test point\u003c\/li\u003e\n\u003cli\u003eWide IF bandwidth: 1\/5\/30 MHz\u003c\/li\u003e\n\u003cli\u003eVersatile calibration techniques: TOSM, TRL\/LRL, TOM, TRM, TNA, UOSM\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration units\u003c\/li\u003e\n\u003cli\u003ePhase and group delay measurements on mixers with and without LO access\u003c\/li\u003e\n\u003cli\u003eFrequency range: 300 kHz to 8 GHz (R\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA8), 10 MHz to 24\/40\/50\/67\/110 GHz (R\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA24\/40\/50\/67\/110)\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eZVA40 Configurations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cstyle\u003e\u003c!--\ntable {\n border-collapse: collapse;\n width: 100%;\n}\n\nth, td {\n text-align: left;\n padding: 8px;\n}\n\ntr:nth-child(even){background-color: #f2f2f2}\n\nth {\n background-color: #a32564;\n color: white;\n}\n--\u003e\u003c\/style\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eRohde \u0026amp; Schwarz ZVA40\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003eModel only\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eConfig 1\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003ca href=\"#pre-order-popup\" class=\"btn-pre-order btn btn-1\"\u003eRequest Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eRohde \u0026amp; Schwarz ZVA40\u003c\/td\u003e\n\u003ctd style=\"width: 40%;\"\u003e\n\u003cspan\u003e4-Port\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB4 - Oven quartz (OCXO)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB16 - Direct generator\/receiver access for 4 port ZVA40\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB18 - Removable flash disk 4 GB\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB21 - Generator step attenuator, port 1\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB23 - Generator step attenuator, port 3\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB32 - Receiver step attenuator, port 2\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eB34 - Receiver step attenuator, port 4\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eK4 - Frequency Conversion\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eK9 - Embedded LO mixer delay measurements\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eConfig 2\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e\u003ca href=\"#pre-order-popup\" class=\"btn-pre-order btn btn-1\"\u003eRequest Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003cdiv id=\"ti_expandedbox_c_t-9660.9\" class=\"tbl col3\"\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA40\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test ports\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 or 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e300 kHz to 8 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 24 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 40 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test points per trace\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 to 60001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eMeasurement bandwidths\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 Hz to 1 MHz (with option: up to 30 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. number of internal sources\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eOperating system\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWindows XP Embedded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDynamic range at 10 Hz measurement bandwidth:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetween test ports\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 135 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eWith direct receiver access\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 145 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 145 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 150 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003ePower range (typ)\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–45 dBm to +15 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +18 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +18 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith optional step attenuators\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eGenerator step attenuators extend the lower limit of the output power range by 70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement time per test point\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 3.5 μs (at 1 MHz measurement bandwidth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003eData transfer time (for 201 measurements points):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evia IEC\/IEEE bus\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 2.9 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003evia VX11 over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evia RSIB over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 0.7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eSwitching time between channels\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching time between instrument setups\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 10 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"ti_expandedbox_c_t-9660.10\" class=\"tbl col3\"\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA67\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u0026amp;S\u003cspan style=\"font-size: 12.5px;\"\u003e \u003c\/span\u003eZVA110\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test ports\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 or 4\u003c\/td\u003e\n\u003ctd\u003e2 (base unit\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eR\u0026amp;S\u003csup\u003e®\u003c\/sup\u003eZVA67:\u003cbr\u003e4 ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 50 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 kHz to 67 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e10 MHz to 110 GHz\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of test points per trace\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 to 60001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eMeasurement bandwidths\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 Hz to 1 MHz (with option: up to 30 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. number of internal sources\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4 (base unit\u003cbr\u003eR\u0026amp;S\u003csup\u003e®\u003c\/sup\u003eZVA67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eOperating system\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWindows XP Embedded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDynamic range at 10 Hz measurement bandwidth:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetween test ports\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 140 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 130 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eWith direct receiver access\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 150 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. \u0026gt; 145 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eOutput power at test port\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 18 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 18 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003etyp. 8 dB\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower range (typ)\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +15 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–40 dBm to +18 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cnobr\u003e–30 dBm to +8 dBm\u003c\/nobr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eWith optional step attenuators\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGenerator step attenuators extend the lower\u003cbr\u003elimit of the output power range by 50 dB\u003c\/td\u003e\n\u003ctd\u003e(no step attneuators)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eMeasurement time per test point\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 3.5 μs (at 1 MHz measurement bandwidth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eData transfer time (for 201 measurements points):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003evia IEC\/IEEE bus\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 2.9 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evia VX11 over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003evia RSIB over 100 Mbit\/s LAN\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 0.7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching time between channels\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 1 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bkgr\"\u003e\n\u003ctd\u003eSwitching time between instrument setups\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026lt; 10 ms (with no more than 2001 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA_Vector_Network_Analyser_-_Specifications.pdf?1411\" title=\"R\u0026amp;S ZVA Vector Network Analyser - Specifications\"\u003eR\u0026amp;S ZVA Vector Network Analyser - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA110_Network_Analyser_-_Specifications.pdf?1410\" title=\"R\u0026amp;S ZVA110 Network Analyser - Specifications\"\u003eR\u0026amp;S ZVA110 Network Analyser - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA-Zxx_Millimeter-Wave_Converters_-_Specifications.pdf?1411\" title=\"R\u0026amp;S ZVA-Zxx Millimeter-Wave Converters - Specifications\"\u003eR\u0026amp;S ZVA-Zxx Millimeter-Wave Converters - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z3xx_T-Checker_-_Specifications.pdf?1411\" title=\"R\u0026amp;S ZV-Z3xx T-Checker - Specifications\"\u003eR\u0026amp;S ZV-Z3xx T-Checker - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVAX-TRM_Extension_Unit_-_Specifications.pdf?1413\" title=\"R\u0026amp;S ZVAX-TRM Extension Unit - Specifications\"\u003eR\u0026amp;S ZVAX-TRM Extension Unit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z129_Calibration_Kits_-_Specifications.pdf?1415\" title=\"R\u0026amp;S ZV-Z129 Calibration Kits - Specifications\"\u003eR\u0026amp;S ZV-Z129 Calibration Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-WRxx_R_S_ZCWM-570_Waveguide_Calibration_Kits_-_Specifications.pdf?1418\" title=\"R\u0026amp;S ZV-WRxx R\u0026amp;S ZCWM-570 Waveguide Calibration Kits - Specifications\"\u003eR\u0026amp;S ZV-WRxx R\u0026amp;S ZCWM-570 Waveguide Calibration Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z4xx_Mechanical_Verification_Kits_-_Specifications.pdf?1417\" title=\"R\u0026amp;S ZV-Z4xx Mechanical Verification Kits - Specifications\"\u003eR\u0026amp;S ZV-Z4xx Mechanical Verification Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVAX24_Extension_Unit_-_Specifications.pdf?1419\" title=\"R\u0026amp;S ZVAX24 Extension Unit - Specifications\"\u003eR\u0026amp;S ZVAX24 Extension Unit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z170_Calibration_Kit_-_Specifications.pdf?1420\" title=\"R\u0026amp;S ZV-Z170 Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-Z170 Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-ZCAN_Calibration_Kit_-_Specifications.pdf?1422\" title=\"R\u0026amp;S ZV-ZCAN Calibration Kit - Specifications\"\u003eR\u0026amp;S ZV-ZCAN Calibration Kit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZCxxx_Millimeter-Wave_Converters_-_Specifications.pdf?1422\" title=\"R\u0026amp;S ZCxxx Millimeter-Wave Converters - Specifications\"\u003eR\u0026amp;S ZCxxx Millimeter-Wave Converters - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z2xx_Calibration_Kits_-_Specifications.pdf?1423\" title=\"R\u0026amp;S ZV-Z2xx Calibration Kits - Specifications\"\u003eR\u0026amp;S ZV-Z2xx Calibration Kits - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z9x_ZV-Z19x_Test_Port_Cables_-_Specifications.pdf?1425\" title=\"R\u0026amp;S ZV-Z9x, ZV-Z19x Test Port Cables - Specifications\"\u003eR\u0026amp;S ZV-Z9x, ZV-Z19x Test Port Cables - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-Z5x_Calibration_Unit_-_Specifications.pdf?1426\" title=\"R\u0026amp;S ZV-Z5x Calibration Unit - Specifications\"\u003eR\u0026amp;S ZV-Z5x Calibration Unit - Specifications\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBrochures\u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA-Zxx_Millimeter_Wave_Converters_-_Product_Brochure.pdf?1427\" title=\"R\u0026amp;S ZVA-Zxx Millimeter Wave Converters - Product Brochure\"\u003eR\u0026amp;S ZVA-Zxx Millimeter Wave Converters - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVA_Vector_Network_Analyzer_-_Product_Brochure.pdf?1428\" title=\"R\u0026amp;S ZVA Vector Network Analyser - Product Brochure\"\u003eR\u0026amp;S ZVA Vector Network Analyser - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/Ground_station_testing_on_satellites_in_orbit.pdf?1428\" title=\"Ground station testing on satellites in orbit\"\u003eGround station testing on satellites in orbit\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZV-ZCAN_Calibration_Kit_-_Product_Brochure.pdf?1430\" title=\"R\u0026amp;S ZV-ZCAN Calibration Kit - Product Brochure\"\u003eR\u0026amp;S ZV-ZCAN Calibration Kit - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_ZVAX_TRM_Extension_Unit_-_Product_Brochure.pdf?1430\" title=\"R\u0026amp;S ZVAX‑TRM Extension Unit - Product Brochure\"\u003eR\u0026amp;S ZVAX‑TRM Extension Unit - Product Brochure\u003c\/a\u003e\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/PDF_logo_pico.png?v=1554975012\" alt=\"PDF Logo\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0182\/3575\/2526\/files\/R_S_LegacyPro_Instrument_emulation_Breathing_new_life_into_existing_test_systems_-_Brochure.pdf?1431\" title=\"R\u0026amp;S LegacyPro Instrument emulation – Breathing new life into existing test systems - Brochure\"\u003eR\u0026amp;S LegacyPro Instrument emulation – Breathing new life into existing test systems - Brochure\u003c\/a\u003e\u003c\/p\u003e"}
    Rohde & Schwarz ZVA40 Vector Network Analyser
    Rohde & Schwarz ZVA40 Vector Network Analyser

    Up to 40 GHz Model Available


    The Rohde & Schwarz ZVA40 is an ideal choice for demanding measurements in the lab and in production – from filter measurements requiring maximum dynamic range to linear and nonlinear measurements on amplifiers and mixers as well as on receivers and transceivers.
    MCS Rentals
    Address: MCS Rentals, Glascoed Road,
    New Vision Business Park,
    St Asaph, Denbighshire.
    LL17 0LP
    Mon - Fri: 09:00 - 17:00 Phone: 01492 643 060
    Email: sales@mcsrentals.com
    Follow us on:
    • About us
    • Contact us
    • Privacy Policy
    • Terms & Conditions

    Registered in England & Wales
    Copyright © 2023 MCS Rentals Ltd
    Registered Company Number: 04147703

      Sample Product

      • Twitter
      • Facebook
      • Google+